Variability of CT Airways Measurements in COPD Patients Between Morning and Afternoon: Comparisons to Variability of Spirometric Measurements.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hackx Maxime, Gyssels Elodie, Severo Garcia Tiago, De Meulder Isabelle, Bruyneel Marie, Van Muylem Alain, Ninane Vincent, Gevenois Pierre Alain

Аннотация

RATIONALE AND OBJECTIVES: Computed tomography (CT) airways measurements can be used as surrogates to spirometric measurements for assessing bronchodilation in a particular patient with chronic obstructive pulmonary disease. Although spirometric measurements show variations within the opening hours of a hospital department, we aimed to compare the variability of CT airways measurements between morning and afternoon in patients with chronic obstructive pulmonary disease to that of spirometric measurements.

MATERIALS AND METHODS: Twenty patients had pulmonary function tests and CT around 8 am and 4 pm. Luminal area (LA) and wall thickness (WT) of third and fourth generation airways were measured twice by three readers. The percentage of airway area occupied by the wall (WA%) and the square root of wall area at an internal perimeter of 10 mm (√WAPi10) were calculated. The effects of examination time, reader, and measurement session on CT airways measurements were assessed, and the variability of these measurements was compared to that of spirometric measurements.

RESULTS: Variability of LA3rd and LA4th was greater than that of spirometric measurements (P values ranging from <.001 to .033). There was no examination time effect on √WAPi10, WT3rd, LA4th, or WA%4th (P values ranging from .102 to .712). There was a reader effect on all CT airways measurements (P values ranging from <.001 to .028), except in WT3rd (P> .999). There was no effect of measurement session on any CT airway measurement (P values ranging from .535 to >.999).

CONCLUSION: As the variability of LA3rd and LA4th is greater than that of spirometric measurements, clinical studies should include cohorts with larger numbers of patients when considering LA than when considering spirometric measurements as end points.