MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14397595.2017.1332540

Медицинская библиотека · Modern rheumatology · 2017

Diagnostic sensitivity of cutoff values of IgG4-positive plasma cell number and IgG4-positive/CD138-positive cell ratio in typical multiple lesions of patients with IgG4-related disease.

Mizushima Ichiro, Yamada Kazunori, Harada Kenichi, Matsui Shoko, Saeki Takako, Kondo Satoru, Takahira Masayuki, Waseda Yuko, Hamaguchi Yasuhito, Fujii Hiroshi, Yamagishi Masakazu, Kawano Mitsuhiro

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study aimed to investigate the diagnostic sensitivity of the cutoff values of IgG4-positive plasma cell (PC) number and IgG4-positive/CD138-positive cell ratio proposed by the International consensus statement (ICS) on the pathology of IgG4-related disease (IgG4-RD) in typical multiple lesions of patients with IgG4-RD.

METHODS

We evaluated IgG4-positive PC number and IgG4-positive/CD138-positive cell ratio in 39 samples from 18 IgG4-RD patients having more than two typical lesions of IgG4-RD.

RESULTS

We evaluated 12 submandibular, 12 ophthalmic, six skin, five kidney, two pancreatic, and one bronchus and prostate lesion each in 18 patients with typical clinical, serological, and radiographic features. Concerning IgG4 + PC number per high-power field, most ophthalmic (11/12), kidney (5/5), pancreatic (2/2), and bronchial lesions (1/1) fulfilled the cutoff value of ICS, whereas many of the submandibular (6/12) and skin lesions (0/6) did not. In contrast to the absolute number, all lesions fulfilled the cutoff value of IgG4+/CD138 + cell ratio. In eight cases, only one or two lesions in the same patient fulfilled the cutoff value of ICS, while the others did not.

CONCLUSIONS

These results suggest that ICS criteria have different sensitivities among the affected organs for the diagnosis of IgG4-RD.

Для цитирования: Mizushima Ichiro, Yamada Kazunori, Harada Kenichi, Matsui Shoko, Saeki Takako, Kondo Satoru, Takahira Masayuki, Waseda Yuko, Hamaguchi Yasuhito, Fujii Hiroshi, Yamagishi Masakazu, Kawano Mitsuhiro. Diagnostic sensitivity of cutoff values of IgG4-positive plasma cell number and IgG4-positive/CD138-positive cell ratio in typical multiple lesions of patients with IgG4-related disease.. Modern rheumatology. 2017. DOI: 10.1080/14397595.2017.1332540.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.