MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/clr.70053

Медицинская библиотека · Clinical oral implants research · 2025

Impact of Marginal Misfit in Implant-Supported Fixed Dental Prostheses on Peri-Implant Bone Levels: A Retrospective Quantitative Analysis.

Couso-Queiruga Emilio, Ramseier Christoph A, Chappuis Vivianne, M Simone F M Janner, Buser Daniel, Brägger Urs, Salvi Giovanni E

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate the impact of the marginal fit of implant-supported prostheses (ISP) on peri-implant bone levels. Additionally, the study aimed to determine a clinically relevant threshold for the radiographic vertical misfit gap at the ISP, when present, and to identify potential risk factors associated with changes in bone levels.

METHODS

This study involved subjects who received ISPs for tooth replacement therapy. Standardized intraoral periapical radiographs were taken 10 years after loading to assess the radiographic distance between the implant shoulder and the most coronal point of crestal bone (DIB). ISP marginal gaps were categorized as no gap or gap, with vertical dimensions categorized as 0 mm, > 0- < 0.1 mm, and ≥ 0.1 mm. A multivariable linear mixed-effect model was applied to control for potential confounders.

RESULTS

A total of 301 patients and 505 implants with a 10.6 ± 0.7 years follow-up were analyzed. ISPs without gaps exhibited statistically significantly lower DIB values (3.22 ± 0.8 mm) than those with gaps (3.43 ± 0.6 mm; p = 0.001). Gaps ≥ 0.1 mm were associated with statistically significantly higher DIB values (3.45 ± 0.7 mm; p = 0.001) compared with gaps between > 0 and < 0.1 mm (3.36 ± 0.5 mm; p = 0.001), or no gaps (3.22 ± 0.7 mm; p = 0.001). Each increment of 0.1 mm in the vertical crestal gap corresponded to a significant increase in DIB values (0.08 mm; p = 0.03). Finally, smoking and a history of periodontitis were independent risk factors for increased DIB.

CONCLUSIONS

Marginal misfit of ISP affects peri-implant bone stability, with gaps ≥ 0.1 mm linked to higher DIB. Smoking and periodontitis are independent risk factors for increased DIB.

Для цитирования: Couso-Queiruga Emilio, Ramseier Christoph A, Chappuis Vivianne, M Simone F M Janner, Buser Daniel, Brägger Urs, Salvi Giovanni E. Impact of Marginal Misfit in Implant-Supported Fixed Dental Prostheses on Peri-Implant Bone Levels: A Retrospective Quantitative Analysis.. Clinical oral implants research. 2025. DOI: 10.1111/clr.70053.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.