Evidence for an influence of mechanical restitution on beat-to-beat variations in haemodynamics during chronic atrial fibrillation in patients.

Hardman S M, Noble M I, Biggs T, Seed W A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

We tested the hypothesis that beat-to-beat changes in haemodynamics during atrial fibrillation include an effect of each preceding R-R interval through the interval-strength relationship (mechanical restitution).

BACKGROUND

The variation in stroke volume and pulse pressure characteristic of atrial fibrillation is usually ascribed to time dependent ventricular filling.

METHODS

We measured the maximum rate of rise of left ventricular pressure (LVdP/dtmax), and aortic blood velocity and its integral in patients with atrial fibrillation undergoing cardiac catheterisation. The contractile response of isometric human myocardial trabeculae to sequences of atrial fibrillation was also studied, using the recorded ECGs as stimuli. The trabeculae were obtained from the resected right ventricular outflow tracts of patients with Fallot's tetralogy undergoing operative correction.

RESULTS

Beat-to-beat variations in contractile function during atrial fibrillation in the patients were recorded as LVdP/dtmax and left ventricular ejection (ascending aortic) velocity integral (proportional to stroke volume). Both these indices correlated well with the response to the same ECG (R wave) sequences in the isometric model measured as the maximum rate of rise of force, dF/dtmax, r = 0.72 to 0.81, p, 0.0001. When short pre-preceding intervals were excluded (minimizing the effect of post-extrasystolic potentiation), these variables showed a positive curvilinear relationship to preceding interval typical of mechanical restitution.

CONCLUSIONS

Mechanical restitution, which causes beat-to-beat changes in inotropic state, accounts in part for the changes in stroke volume in atrial fibrillation.

Для цитирования: Hardman S M, Noble M I, Biggs T, Seed W A. Evidence for an influence of mechanical restitution on beat-to-beat variations in haemodynamics during chronic atrial fibrillation in patients.. Cardiovascular research. 1998. DOI: 10.1016/s0008-6363(97)00318-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.