The American journal of cardiology · 1997
Effect of electrode position on outcome of low-energy intracardiac cardioversion of atrial fibrillation.
Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Alt E, Schmitt C, Ammer R, Plewan A, Evans F, Pasquantonio J, Ideker T, Lehmann G, Pütter K, Schömig A
Аннотация
The aim of this study was to evaluate the new method of low-energy, catheter-based intracardiac cardioversion in patients with chronic atrial fibrillation (AF) and to compare 2 different lead positions. Accordingly, we prospectively studied 80 consecutive patients with chronic AF (9.8 +/- 7.9 months) who were randomly assigned to undergo internal cardioversion either via defibrillation electrodes placed in the right atrium and coronary sinus (coronary sinus group) or via defibrillation electrodes placed in the right atrium and left pulmonary artery (pulmonary artery group). Intracardiac shocks were delivered by an external defibrillator synchronized to the QRS complex. After conversion, all patients were treated orally with sotalol (mean daily dose, 189 +/- 63 mg/day). For conversion to sinus rhythm, the overall mean energy requirement was 5.6 +/- 3.1 J. In the coronary sinus group, cardioversion was achieved in 35 of 38 patients at a mean energy level of 4.1 +/- 2.3 J (range 1.0 to 9.9), and in the pulmonary artery group in 39 of 42 patients with 7.2 +/- 3.1 J (range 2.5 to 14.8). Although there was no difference with regard to success rate, the energy differed significantly between the 2 groups (p < 0.01). Mean lead impedance was 56.4 +/- 7.0 omega and 54.6 +/- 8.5 omega, respectively (p = NS). No serious complications were observed in either lead group. At a mean follow-up of 14.2 +/- 7.0 months, 54% and 56%, respectively, of patients who had been converted successfully remained in sinus rhythm. Thus, low-energy biphasic shocks delivered between the right atrium and coronary sinus or pulmonary artery are equally effective for cardioversion of patients with chronic AF. The energy requirements for conversion from a pulmonary artery electrode position are higher than for the coronary sinus position.
Предметные рубрики MeSH
Administration, OralAdultAgedAnti-Arrhythmia AgentsAtrial FibrillationCardiac CatheterizationChronic DiseaseCoronary VesselsElectric ConductivityElectric CountershockElectric ImpedanceElectrocardiographyElectrodes, ImplantedFemaleFollow-Up StudiesHeart AtriaHeart RateHumansMaleMiddle AgedProspective StudiesPulmonary ArterySotalolTreatment Outcome