Differentiation between adrenocortical carcinoma and lipid-poor adrenal adenoma using a multiparametric MRI-based diagnostic algorithm.

Oloukoi Carmelia, Dohan Anthony, Gaillard Martin, Hoeffel Christine, Groussin-Rouiller Lionel, Bertherat Jérome, Jouinot Anne, Assié Guillaume, Fuks David, Sibony Mathilde, Soyer Philippe, Jannot Anne-Sophie, Barat Maxime

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this study was to evaluate the capabilities of multiparametric magnetic resonance imaging (MRI) in differentiating between lipid-poor adrenal adenoma (LPAA) and adrenocortical carcinoma (ACC).

MATERIALS AND

METHODS

Patients of two centers who underwent surgical resection of LPAA or ACC after multiparametric MRI were retrospectively included. A training cohort was used to build a diagnostic algorithm obtained through recursive partitioning based on multiparametric MRI variables, including apparent diffusion coefficient and chemical shift signal ratio (i.e., tumor signal intensity index). The diagnostic performances of the multiparametric MRI-based algorithm were evaluated using a validation cohort, alone first and then in association with adrenal tumor size using a cut-off of 4 cm. Performances of the diagnostic algorithm for the diagnosis of ACC vs. LPAA were calculated using pathology as the reference standard.

RESULTS

Fifty-four patients (27 with LPAA and 27 with ACC; 37 women; mean age, 48.5 ± 13.3 [standard deviation (SD)] years) were used as the training cohort and 61 patients (24 with LPAA and 37 with ACC; 47 women; mean age, 49 ± 11.7 [SD] years) were used as the validation cohort. In the validation cohort, the diagnostic algorithm yielded best accuracy for the diagnosis of ACC vs. LPAA (75%; 46/61; 95% CI: 55-88) when used without lesion size. Best sensitivity was obtained with the association of the diagnostic algorithm with tumor size (96%; 23/24; 95% CI: 80-99). Best specificity was obtained with the diagnostic algorithm used alone (76%; 28/37; 95% CI: 60-87).

CONCLUSION

A multiparametric MRI-based diagnostic algorithm that includes apparent diffusion coefficient and tumor signal intensity index helps discriminate between ACC and LPAA with high degrees of specificity and accuracy. The association of the multiparametric MRI-based diagnostic algorithm with adrenal lesion size helps maximize the sensitivity of multiparametric MRI for the diagnosis of ACC.

Для цитирования: Oloukoi Carmelia, Dohan Anthony, Gaillard Martin, Hoeffel Christine, Groussin-Rouiller Lionel, Bertherat Jérome, Jouinot Anne, Assié Guillaume, Fuks David, Sibony Mathilde, Soyer Philippe, Jannot Anne-Sophie, Barat Maxime. Differentiation between adrenocortical carcinoma and lipid-poor adrenal adenoma using a multiparametric MRI-based diagnostic algorithm.. Diagnostic and interventional imaging. 2024. DOI: 10.1016/j.diii.2024.03.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.