m+Medelevator.RU
← Поиск публикаций
Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2026

Clinical validation of a voice-based AI tool for screening cognitive impairment: a prospective multicenter study.

СтатьяМногоцентровое исследованиеВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yoon Bora, Lee Hyuk-Je, Kim Woojun, Shim Yong Soo, Lim Eun Ye, Cho A-Hyun, Song In Wook, Hong Yun Jeong, Shin Hye Eun, Ku Bon D, Cho Soo Hyun, Ku Hyejin, Shin Dong-Hoon, Yang Dong Won

Аннотация

BACKGROUND: Early, scalable screening for cognitive impairment is needed beyond traditional paper-and-pencil tools.

OBJECTIVE: To evaluate the diagnostic accuracy and usability of SPICK, a Korean-language, voice-based cognitive screener.

METHODS: In a prospective multicenter validation study (ITT N = 399), the reference diagnosis cognitively impaired (mild cognitive impairment [MCI] or Alzheimer's dementia [AD]) or cognitively unimpaired (CU) was determined independently by board-certified neurologists; SPICK provided the index test result. The primary endpoint was SPICK sensitivity and specificity versus prespecified thresholds (≥ 80% and ≥ 59%). Secondary endpoints included subgroup performance (MCI vs CU; AD vs CU), accuracy, area under the receiver operating characteristic (ROC) curve [AUC], and System Usability Scale (SUS).

RESULTS: For cognitive impairment detection, SPICK achieved sensitivity 85.71% (95% confidence interval [CI] 81.46-89.31%) and specificity 74.29% (62.44-83.99%), meeting thresholds; AUC 0.800 and accuracy 83.71%. Subgroup analyses showed MCI sensitivity 79.64% (72.73-85.47%) and specificity 74.29% (62.44-83.99%), and AD sensitivity 91.98% (86.67-95.66%) and specificity 74.29% (62.44-83.99%). Among 395 participants with usability data, mean SUS was 67.32 (SD 19.10; median 70.0).

CONCLUSION: SPICK demonstrated clinically meaningful accuracy with acceptable usability, supporting its potential as an automated, voice-based screening tool for diverse clinical settings.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты