MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aos.17591

Медицинская библиотека · Acta ophthalmologica · 2025

Customizing AI-based screening with real-world data: Practical insights from diabetic retinopathy.

Poschkamp Broder, Kantz Liane, Augstein Petra, Tayar Allam, Kaderali Lars, Busch Martin, Bohl Beathe, Paul Sebastian, Lüdtke Lisa, Bründer Marie-Christine, Schulz Daniel, Grabow Hanna, Dipl Elke Gens, Müller Antonia, Martin Emily, Kerner Wolfgang, Reindel Jörg, Stahl Andreas

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: Diabetic retinopathy (DR) is a leading cause of vision loss in middle-aged adults globally. Although artificial intelligence (AI)-based screening tools like IDx-DR (classification) and Thirona RetCAD (regression) have shown high sensitivity in controlled settings, real-world screening faces challenges due to missing or low-quality images and inadequate adaptation to local healthcare needs. The objective was to compare the performance of two AI-based DR screening algorithms (IDx-DR and RetCAD) that analyse non-mydriatic images, against ophthalmologists' mydriatic fundoscopy with image analysis and the impact of customized referral threshold modification ('Greifswald modification') on screening outcomes.

METHODS

This one-centre observational study included 1716 patients with diabetes mellitus (Clinical Trials Register: DRKS00035967). Sensitivity, specificity, the proportion of ungradable images and the reduction in ophthalmologic evaluations were assessed. Customized referral threshold modification was conducted using the Youden Index.

RESULTS

In 98 patients (5.7%), no images could be acquired, and 35 patients (2.1%) had incomplete image sets for IDx-DR. IDx-DR rejected 438 patients (25.5%) due to image quality, while RetCAD flagged 134 eyes from 120 patients (6.9%) but provided output for all. Among analysable images, sensitivities ranged from 70.4% (RetCAD) to 93.6% (RetCAD with Greifswald modification). Including all patients reduced sensitivity from 52.7% (IDx-DR) to 79.9% (RetCAD with Greifswald modification). AI screening reduced ophthalmologic exam needs by 47.5% to 78.5%.

CONCLUSIONS

Real-world DR screening performance of AI algorithms, when including non-analysable patients, can be substantially lower than in controlled studies. The use of regression algorithms enabled the customization of referral thresholds, improving screening accuracy and reducing the clinical burden.

Для цитирования: Poschkamp Broder, Kantz Liane, Augstein Petra, Tayar Allam, Kaderali Lars, Busch Martin, Bohl Beathe, Paul Sebastian, Lüdtke Lisa, Bründer Marie-Christine, Schulz Daniel, Grabow Hanna, Dipl Elke Gens, Müller Antonia, Martin Emily, Kerner Wolfgang, Reindel Jörg, Stahl Andreas. Customizing AI-based screening with real-world data: Practical insights from diabetic retinopathy.. Acta ophthalmologica. 2025. DOI: 10.1111/aos.17591.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.