Performance of the Bio-Rad Geenius HIV1/2 Supplemental Assay in Detecting "Recent" HIV Infection and Calculating Population Incidence.

Keating Sheila M, Kassanjee Reshma, Lebedeva Mila, Facente Shelley N, MacArthur Jeffrey C, Grebe Eduard, Murphy Gary, Welte Alex, Martin Jeffrey N, Little Susan, Price Matthew A, Kallas Esper G, Busch Michael P, Pilcher Christopher D

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

HIV seroconversion biomarkers are being used in cross-sectional studies for HIV incidence estimation. Bio-Rad Geenius HIV-1/2 Supplemental Assay is an immunochromatographic single-use assay that measures antibodies (Ab) against multiple HIV-1/2 antigens. The objective of this study was to determine whether the Geenius assay could additionally be used for recency estimation.

DESIGN

This assay was developed for HIV-1/2 confirmation; however, quantitative data acquired give information on increasing concentration and diversity of antibody responses over time during seroconversion. A quantitative threshold of recent HIV infection was proposed to determine "recent" or "nonrecent" HIV infection; performance using this cutoff was evaluated.

METHODS

We tested 2500 highly characterized specimens from research subjects in the United States, Brazil, and Africa with well-defined durations of HIV infection. Regression and frequency estimation were used to estimate assay properties relevant to HIV incidence measurement: mean duration of recent infection (MDRI), false-recent rate, and assay reproducibility and robustness.

RESULTS

Using the manufacturer's proposed cutoff index of 1.5 to identify "recent" infection, the assay has an estimated false-recent rate of 4.1% (95% CI: 2.2 to 7.0) and MDRI of 179 days (155 to 201) in specimens from treatment-naive subjects, presenting performance challenges similar to other incidence assays. Lower index cutoffs associated with lower MDRI gave a lower rate of false-recent results.

CONCLUSIONS

These data suggest that with additional interpretive analysis of the band intensities using an algorithm and cutoff, the Geenius HIV-1/2 Supplemental Assay can be used to identify recent HIV infection in addition to confirming the presence of HIV-1 and HIV-2 antibodies.

Для цитирования: Keating Sheila M, Kassanjee Reshma, Lebedeva Mila, Facente Shelley N, MacArthur Jeffrey C, Grebe Eduard, Murphy Gary, Welte Alex, Martin Jeffrey N, Little Susan, Price Matthew A, Kallas Esper G, Busch Michael P, Pilcher Christopher D. Performance of the Bio-Rad Geenius HIV1/2 Supplemental Assay in Detecting "Recent" HIV Infection and Calculating Population Incidence.. Journal of acquired immune deficiency syndromes (1999). 2016. DOI: 10.1097/qai.0000000000001146.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.