The force required to induce hemivein pulsation is associated with the site of maximum field loss in glaucoma.
Аннотация
PURPOSE: To determine the factors associated with central retinal vein pulsation changes in glaucoma and identify any hemiretinal vein pulsation changes and their association with sectoral visual field loss.
METHODS
One hundred twenty-six patients with glaucoma and 40 normal subjects had automated perimetry, blood pressure, and intraocular pressure measured. A hemifield sensitivity loss was calculated from the upper and lower halves of each field. Those without spontaneous venous pulsation on the optic disc had an ophthalmodynamometer applied, to measure the minimum ophthalmodynamometric force (ODF) necessary to induce venous pulsation. When ODF was restricted to the hemiveins, the force needed to induce pulsation in each hemivein was measured.
RESULTS
Eighty-three patients with glaucoma had no spontaneous venous pulsation. The minimum ODF was strongly correlated with mean deviation (Spearman rank r = -0.475, P < 0.0001). Mixed linear regression analysis showed that mean deviation (P < 0.0001) and pulse blood pressure (P < 0.0001) were significantly associated with minimum ODF. There was a strong association between differences in hemifield sensitivity loss and in hemivein ODF (rank r = 0.369, P < 0.0001, n = 80). Multiple linear regression modeling demonstrated that lower hemivein ODF was independently associated with upper field loss (P = 0.003) and upper hemivein ODF with lower field loss (P < 0.0001).
CONCLUSIONS
These venous pulsation findings in glaucoma are independent of blood pressure. The hemifield and hemivein association suggests that the major hemivein change is adjacent to the site of major disc damage.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.