m+Medelevator.RU
← Поиск публикаций
PloS one · 2013

Usefulness of high suction pressure for sufficient tissue collection during endobronchial ultrasound guided transbronchial needle aspiration.

Клиническое исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shiroyama Takayuki, Okamoto Norio, Suzuki Hidekazu, Tamiya Motohiro, Yamadori Tadahiro, Morishita Naoko, Otsuka Tomoyuki, Morita Satomu, Kurata Kanako, Okimura Akira, Kawahara Kunimitsu, Sasada Shinji, Hirashima Tomonori, Kawase Ichiro

Аннотация

INTRODUCTION: The optimal suction pressure during endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) remains to be determined. The aim of this study was to compare suction pressures for performance in collecting sufficient tissue specimens from mediastinal and hilar lymph nodes during EBUS-TBNA.

METHODS: Retrospective analysis of consecutive patients with mediastinal and hilar lymphadenopathy who underwent EBUS-TBNA over a 3-year period. Results from patients who underwent EBUS-TBNA using a dedicated 20-mL VacLoc (Merit Medical Systems, Inc, South Jordan, UT) syringe (conventional method, group C) were compared with results from patients in whom a disposable 30-mL syringe (high pressure group, group H) was used. The yield for sufficient histologic specimen retrieval and amount of tissue obtained were compared between the 2 groups.

RESULTS: Of 178 patients who underwent EBUS-TBNA, 131 had lung cancer confirmed by EBUS-TBNA: 35 in group C and 96 in group H. There were 7 patients in group C and 6 in group H who received final diagnoses by cytology alone. There were 28 in group C and 90 in group H who were diagnosed by both cytology and histology. There was a statistically significant difference between the groups in terms of the rate of sufficient sampling for histological specimens (p = 0.04). The H group revealed a tissue area approximately twice that of the C group (p = 0.003). There were no major procedure-related complications in either group.

CONCLUSION: Higher suction pressures with larger syringe volumes during EBUS-TBNA may be useful for safely collecting sufficient tissue specimens.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты