MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rlu.0000000000000272

Медицинская библиотека · Clinical nuclear medicine · 2014

Dual-isotope 99mTc-MIBI/123I parathyroid scintigraphy in primary hyperparathyroidism: comparison of subtraction SPECT/CT and pinhole planar scan.

Hassler Stéphanie, Ben-Sellem Dorra, Hubele Fabrice, Constantinesco Andre, Goetz Christian

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: In patients with primary hyperparathyroidism, the preoperative imaging objective is to locate accurately and reliably uniglandular or multiglandular hyperfunctioning parathyroid, to guide surgery, particularly for minimally invasive method. Subtraction planar scintigraphy with dual-isotope (I/Tc-MIBI) is an efficient examination to specify abnormal parathyroid location, but without accurate anatomic reference. This lack should be avoided by a hybrid SPECT/CT image acquisition.

METHODS

We compared planar scans (neck and mediastinum parallel-hole, associated with anterior neck pinhole) to neck and mediastinum SPECT/CT, all with subtraction (I/Tc-MIBI) method, in exact location of abnormal parathyroid in 50 patients with sporadic primary hyperparathyroidism. Surgical and histological findings were used as the standard of comparison.

RESULTS

Sensitivity is equivalent for the 2 protocols (86% and 75% for SPECT/CT and planar protocol, respectively, P = 0.15), but SPECT/CT was highly specific (specificity 100% and 90% for SPECT/CT and planar protocol, respectively, P = 0.04). In patients with concomitant thyroid disease, subtraction SPECT/CT appeared to be more sensitive than planar protocol (88% and 62% for SPECT/CT and planar protocol, respectively, P = 0.04).

CONCLUSIONS

In preoperative assessment of primary hyperparathyroidism and to guide surgery, we propose to perform first subtraction SPECT/CT and to complete it with neck pinhole, only if tomoscintigraphy is negative.

Для цитирования: Hassler Stéphanie, Ben-Sellem Dorra, Hubele Fabrice, Constantinesco Andre, Goetz Christian. Dual-isotope 99mTc-MIBI/123I parathyroid scintigraphy in primary hyperparathyroidism: comparison of subtraction SPECT/CT and pinhole planar scan.. Clinical nuclear medicine. 2014. DOI: 10.1097/rlu.0000000000000272.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.