MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0033-1344217

Медицинская библиотека · Endoscopy · 2013

Feasibility and efficiency of a new 22G core needle: a prospective comparison study.

Hucl Tomas, Wee Eric, Anuradha Sekaran, Gupta Rajesh, Ramchandani Mohan, Rakesh Kalpala, Shrestha Ramila, Reddy Duvvuru Nageshwar, Lakhtakia Sundeep

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND STUDY AIMS: Histological examination of core tissue samples may have advantages over cytology in endoscopic ultrasound (EUS)-guided sampling. We aimed to evaluate the feasibility and efficiency of a new 22G core biopsy needle.

PATIENTS AND

METHODS

Consecutive patients with a pancreatic mass lesion or peri-intestinal lymphadenopathy sequentially underwent fine needle biopsy with both a newly developed 22G core needle (the FNB needle) and a standard 22G fine needle aspiration (FNA) needle, in randomized order.

RESULTS

In 144 patients, mean age 48 years (± standard deviation [SD] 14; range 18 - 82), with 145 lesions (mean lesion size 39 ± 15 mm, range 15 - 99), EUS-guided sampling was technically feasible with both needles in all patients. Mean number of passes to obtain sufficient tissue was 1.2 ± 0.5 with the core needle vs. 2.5 ± 0.9 with the standard needle (P < 0.001). FNB specimens were adequate for evaluation in 125 (86.2 %) vs. 127 (87.6 %) with FNA (P = 0.72). Among 139 patients available for follow-up, FNB provided a correct diagnosis in 110 (79.1 %) and FNA in 112 (80.6 %) (P = 0.73). Sensitivity, specificity, positive and negative predictive values, and accuracy for diagnosis of malignancy were 90 %, 100 %, 100 %, 93 %, 96 % for FNB and 77 %, 100 %, 100 %, 85 %, 92 % for FNA, respectively (P > 0.05).

CONCLUSION

FNB with the new 22G core needle was technically feasible, efficient and comparable to FNA with a standard needle. The core needle required fewer passes to provide an adequate sample, offering potentially shorter procedure time.

Для цитирования: Hucl Tomas, Wee Eric, Anuradha Sekaran, Gupta Rajesh, Ramchandani Mohan, Rakesh Kalpala, Shrestha Ramila, Reddy Duvvuru Nageshwar, Lakhtakia Sundeep. Feasibility and efficiency of a new 22G core needle: a prospective comparison study.. Endoscopy. 2013. DOI: 10.1055/s-0033-1344217.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.