DOI 10.1053/jcan.2002.125147

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2002

Does intraoperative transesophageal echocardiography predict pulmonary valve dysfunction during the Ross procedure?

Gomez Carmen B, Stutzbach Pablo G, Guevara Eduardo, Favaloro Roberto R

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To determine the value of intraoperative transesophageal echocardiography for the assessment of the pulmonary valve anatomy and the pulmonary autograft performance in patients undergoing the Ross procedure.

DESIGN

Open, prospective, observational survey.

SETTING

Favaloro Foundation, single institution.

PARTICIPANTS

Consecutive patients undergoing elective Ross procedure (n = 87).

INTERVENTIONS: Pulmonary valve function and anatomy were assessed by transesophageal echocardiography and the surgeon. Pulmonary autograft function was assessed after implantation. Regurgitation was considered mild (+/4), moderate (++/4), moderate-to-severe (+++/4), and severe (++++/4). Patients were restudied during midterm follow-up.

MEASUREMENTS AND MAIN

RESULTS

The Ross procedure was done in 74 patients (85%). Overall mortality was 3.4%. Mean follow-up was 24 +/- 13 months. The Ross procedure was not done in 13 patients (15%): 6 patients had a bicuspid pulmonary valve, 6 patients had >3 mm fenestrations, and 1 patient had regurgitation. The surgeon diagnosed anomalies in the pulmonary valve through direct observation. Transesophageal echocardiography was not sensitive enough to diagnose pulmonary valve defects in 12 of 13 patients with anomalies. Pulmonary valve regurgitation was identified by intraoperative transesophageal echocardiography in only 1 patient. Autograft regurgitation was 1.07 +/- 0.35 at postoperative evaluation. At 1, 6, and 12 months, it was 1.25 +/- 0.7 (p = 0.18), 1.27 +/- 0.9 (p = 0.185), and 1.29 +/- 0.8 (p = 0.17). The difference in values was not statistically significant. Four patients (5.4%) showed an increase in regurgitation during the first transthoracic autograft control.

CONCLUSION

Intraoperative transesophageal echocardiography allows assessment of autograft performance after implantation. This method is not helpful, however, in detecting pulmonary valve anatomic anomalies.

Для цитирования: Gomez Carmen B, Stutzbach Pablo G, Guevara Eduardo, Favaloro Roberto R. Does intraoperative transesophageal echocardiography predict pulmonary valve dysfunction during the Ross procedure?. Journal of cardiothoracic and vascular anesthesia. 2002. DOI: 10.1053/jcan.2002.125147.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.