Comparative Analysis of 24-Hour Post-Polymerisation Colour Change in Experimental Rice Husk Silica-Incorporated Flowable Composites with Different Photoinitiator Systems Across Three Colour-Assessment Devices.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zaki Aqil Thaqif Rayyan, Abuhijleh Eyas, Mohammed Mithaq R, Al-Rawas Matheel, Fatalla Abdalbseet A, Ariff Tengku Fazrina Tengku Mohd, Abdullah Johari Yap, Yhaya Mohd Firdaus, Noorani Tahir Yusuf
Аннотация
BACKGROUND/OBJECTIVES: Rice husk silica (RHS) is a biosustainable filler with potential application in dental flowable composites (FCs). However, early post-polymerisation colour change in RHS-incorporated FCs may vary with material formulation, particularly resin composition and photoinitiator system, and may also be affected by the colour-assessment device used. This study compared the 24 h post-polymerisation colour change of 10 experimental RHS-incorporated FC groups formulated with five photoinitiator systems and two commercial FCs used as control, using three colour-assessment devices.
METHODS: Two UDMA/TEGDMA formulations (U50 and U40), each containing 50 wt% nanohybrid RHS, were prepared with different photoinitiator systems (CQ, PPD, CQ/PPD, BAPO, or TPO). CIELAB coordinates were recorded immediately after curing and after 24 h of dry, dark storage at 37 °C using D1 (VITA Easyshade), D2 (Ds-700d Portable Spectrophotometer), and D3 (ColorMeter Pro). The same specimens were measured with all three devices, with five matched specimens from each of the 12 composite groups (N = 60). A mixed repeated-measures ANOVA was performed with device as the within-subject factor and composite as the between-subject factor; agreement was additionally assessed using Bland-Altman analysis and an absolute-agreement intraclass correlation coefficient (ICC).
RESULTS: Device, composite, and the device × composite interaction were significant (all p < 0.001). Estimated mean ΔE*ab was highest for D1 (5.019), followed by D3 (2.368) and D2 (1.777), and all device pairs differed significantly after Bonferroni adjustment. Bland-Altman analysis showed systematic positive bias for D1 relative to D2 and D3. The absolute-agreement ICC was 0.130 (95% CI 0.078-0.177), indicating poor agreement.
CONCLUSIONS: The magnitude of early 24 h colour change depended on both the composite material and the measurement device. The three devices should not be assumed to be directly interchangeable for ΔE*ab assessment; the same calibrated device should be used throughout a longitudinal comparison.
METHODS: Two UDMA/TEGDMA formulations (U50 and U40), each containing 50 wt% nanohybrid RHS, were prepared with different photoinitiator systems (CQ, PPD, CQ/PPD, BAPO, or TPO). CIELAB coordinates were recorded immediately after curing and after 24 h of dry, dark storage at 37 °C using D1 (VITA Easyshade), D2 (Ds-700d Portable Spectrophotometer), and D3 (ColorMeter Pro). The same specimens were measured with all three devices, with five matched specimens from each of the 12 composite groups (N = 60). A mixed repeated-measures ANOVA was performed with device as the within-subject factor and composite as the between-subject factor; agreement was additionally assessed using Bland-Altman analysis and an absolute-agreement intraclass correlation coefficient (ICC).
RESULTS: Device, composite, and the device × composite interaction were significant (all p < 0.001). Estimated mean ΔE*ab was highest for D1 (5.019), followed by D3 (2.368) and D2 (1.777), and all device pairs differed significantly after Bonferroni adjustment. Bland-Altman analysis showed systematic positive bias for D1 relative to D2 and D3. The absolute-agreement ICC was 0.130 (95% CI 0.078-0.177), indicating poor agreement.
CONCLUSIONS: The magnitude of early 24 h colour change depended on both the composite material and the measurement device. The three devices should not be assumed to be directly interchangeable for ΔE*ab assessment; the same calibrated device should be used throughout a longitudinal comparison.