MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.26427

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2016

Influence of distal extension of false lumen on adverse aortic events after TEVAR in patients with acute type B aortic dissection.

Du Zhan-kui, Wang Ya, Wang Xiao-zeng, Jing Quan-min, Han Ya-ling

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To investigate the clinical outcomes influenced by distal extension of false lumen in acute type B aortic dissection (TBAD) patients following thoracic endovascular aortic repair (TEVAR).

METHODS

From April 2002 to January 2013, 264 TBAD patients treated with TEVAR were retrospectively enrolled. The IIIa group exhibited a distal false lumen above the diaphragm (n = 70), and the IIIb group exhibited a distal false lumen under the diaphragm (n = 194). The morphological characteristics and adverse events (30-day and >30 days) were recorded and evaluated.

RESULTS

There were no significant differences between the two groups regarding the demographics, comorbidity profiles, or initial feature of computed tomography angiography. The incidence of true lumen compression and branch involvement were significantly increased in the IIIb group compared with the IIIa group (8.6% vs. 25.3%, respectively; 15.7% vs. 36.1%, respectively, both P < 0.05). The 30-day mortality rate was 1.0% (2/194) in the IIIb group, whereas the IIIa group was zero. The incidence of early adverse events, the 5-year cumulative freedom from adverse events, and the 5-year cumulative freedom from all-cause mortality rate were not significantly different between the IIIa and IIIb groups (2.9% vs. 6.7%, 81.4%, and 80.4%, and 95.7% vs. 93.8%, respectively, all P > 0.05). Log-rank tests also indicated there was no significant difference.

CONCLUSIONS

There was no significant difference between the IIIa and IIIb groups in the 5-year morality and adverse aortic events following TEVAR. The distal extension of false lumen prior to TEVAR does not influence the long-term morality and adverse aortic events in acute TBAD.

Для цитирования: Du Zhan-kui, Wang Ya, Wang Xiao-zeng, Jing Quan-min, Han Ya-ling. Influence of distal extension of false lumen on adverse aortic events after TEVAR in patients with acute type B aortic dissection.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2016. DOI: 10.1002/ccd.26427.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.