MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/bjs.7279

Медицинская библиотека · The British journal of surgery · 2010

Rho kinase signalling mediates radiation-induced inflammation and intestinal barrier dysfunction.

Mihaescu A, Santén S, Jeppsson B, Thorlacius H

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Radiotherapy is important in the management of pelvic malignancies, but radiation-induced intestinal damage is a dose-limiting factor. Microvascular injury and epithelial barrier dysfunction are considered to be rate-limiting aspects in radiation-induced enteropathy. This study investigated the role of Rho kinase signalling in radiation-induced inflammation and intestinal barrier dysfunction.

METHODS

The specific Rho kinase inhibitor Y-27632 (1 and 10 mg/kg) was given to C57BL/6J mice before challenge with 20 Gy radiation. Leucocyte- and platelet-endothelium interactions in the colonic microcirculation were assessed by intravital microscopy. Levels of myeloperoxidase (MPO) and CXC chemokines (macrophage inflammatory protein 2 and cytokine-induced neutrophil chemoattractant), and intestinal leakage were quantified after 16 h.

RESULTS

Radiation increased leucocyte and platelet recruitment, MPO activity, CXC chemokine production and intestinal leakage. Y-27632 significantly reduced radiation-induced leucocyte rolling and abolished adhesion; it also decreased platelet rolling and adhesion by 55 and 74 per cent respectively (P < 0·050). Inhibition of Rho kinase signalling significantly decreased radiation-provoked formation of CXC chemokines, MPO activity by 52 per cent, and intestinal leakage by 67 per cent (P < 0·050).

CONCLUSION

Rho kinase activity constitutes an important signalling mechanism in radiation-induced inflammation and intestinal barrier dysfunction.

Для цитирования: Mihaescu A, Santén S, Jeppsson B, Thorlacius H. Rho kinase signalling mediates radiation-induced inflammation and intestinal barrier dysfunction.. The British journal of surgery. 2010. DOI: 10.1002/bjs.7279.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.