The Annals of thoracic surgery · 1999
Aortic root replacement with the pulmonary autograft: an invariably competent aortic valve?
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Dossche K M, de la Riviére A B, Morshuis W J, Schepens M A, Ernst S M, van den Brand J J
Аннотация
BACKGROUND: Pulmonary autograft aortic root replacement was used in adults. Risk factors for aortic regurgitation (AR), and for pulmonary allograft valve stenosis are identified.
METHODS: From February 1991 through April 1998, 80 adults (mean age 34.4 years) underwent pulmonary autograft aortic root replacement. Primary diagnosis was AR in 43 (53.7%) patients, aortic stenosis in 13 (16.3%) and mixed disease in 24 (30%) patients. A root reinforcement ring was used in 32 (40%) patients.
RESULTS: There was no hospital mortality. Estimated patient survival is 100% at 7 years. A total of 3 patients underwent reoperation: 2 on the autograft for severe AR, 1 for pulmonary allograft stenosis. Freedom from reoperation on the autograft is 96.7 +/- 2.4% at 7 years. Multivariate analysis indicated bicuspid aortic valve disease as an incremental risk factor for AR at discharge (p = 0.036, odds 3.5). Univariate analysis identified operation for pure AR as risk factor for AR during follow-up (p = 0.041). Mild AR or more increased from 2.5% at discharge to 11.3% during follow-up (p = 0.008). Progression of AR was limited by the use of a reinforcement root ring (p = 0.031). Freedom from mild AR or more in patients with and without a reinforcement root ring was 100% and 72.9 +/- 9.3% respectively, at 5 years (p = 0.119). Pulmonary allograft stenosis occurred in 15 (22.5%) patients. Multivariate analysis revealed that large sized pulmonary allografts were less prone to stenosis (p = 0.048, odds 0.13).
CONCLUSIONS: Pulmonary autograft root replacement can be performed with few complications. During follow-up, a significant increase in mild AR or more is observed. The use of a reinforcement root ring is effective in preventing progression of AR.
METHODS: From February 1991 through April 1998, 80 adults (mean age 34.4 years) underwent pulmonary autograft aortic root replacement. Primary diagnosis was AR in 43 (53.7%) patients, aortic stenosis in 13 (16.3%) and mixed disease in 24 (30%) patients. A root reinforcement ring was used in 32 (40%) patients.
RESULTS: There was no hospital mortality. Estimated patient survival is 100% at 7 years. A total of 3 patients underwent reoperation: 2 on the autograft for severe AR, 1 for pulmonary allograft stenosis. Freedom from reoperation on the autograft is 96.7 +/- 2.4% at 7 years. Multivariate analysis indicated bicuspid aortic valve disease as an incremental risk factor for AR at discharge (p = 0.036, odds 3.5). Univariate analysis identified operation for pure AR as risk factor for AR during follow-up (p = 0.041). Mild AR or more increased from 2.5% at discharge to 11.3% during follow-up (p = 0.008). Progression of AR was limited by the use of a reinforcement root ring (p = 0.031). Freedom from mild AR or more in patients with and without a reinforcement root ring was 100% and 72.9 +/- 9.3% respectively, at 5 years (p = 0.119). Pulmonary allograft stenosis occurred in 15 (22.5%) patients. Multivariate analysis revealed that large sized pulmonary allografts were less prone to stenosis (p = 0.048, odds 0.13).
CONCLUSIONS: Pulmonary autograft root replacement can be performed with few complications. During follow-up, a significant increase in mild AR or more is observed. The use of a reinforcement root ring is effective in preventing progression of AR.