DOI 10.1016/0735-1097(94)00404-e
Clinical evaluation of left heart Doppler contrast enhancement by a saccharide-based transpulmonary contrast agent. The Levovist Cardiac Working Group.
Аннотация
OBJECTIVES
A multicenter study was carried out to evaluate the efficacy with which SHU 508A enhances left heart Doppler signals and improves the clinical quantification of valve disease.
BACKGROUND
Poor signal-to-noise ratio often limits the Doppler interrogation of left heart flows. This problem may be resolved by the enhancement of Doppler signals by an ultrasound contrast agent capable of pulmonary transmission, such as the recently developed SHU 508A.
METHODS
Left heart contrast enhancement was tested for 1) continuous wave Doppler evaluation in 51 patients with aortic stenosis, 2) pulsed Doppler transthoracic evaluation of pulmonary venous flow in 85 patients, and 3) color Doppler evaluation of mitral regurgitation in 60 patients. Studies were performed immediately before and during the intravenous administration of SHU 508A (16 ml of 200 mg/ml) and compared with unenhanced transesophageal data in representative subsets of patients.
RESULTS
SHU 508A had no serious adverse effects. A significant increase in left heart Doppler signal intensity lasted for 30 to 300 s. The continuous wave Doppler velocity envelope was enhanced for all jets, but Doppler peak velocity was not altered in high quality baseline studies. However, Doppler contrast enhancement resulted in higher measured peak gradients (p < 0.001) in 29 patients with aortic stenosis who had poor quality baseline studies. This improved the overall correlation with invasive pressure measurements (r = 0.73 vs. r = 0.89, p < 0.01). The enhanced pulsed Doppler traces of transthoracic pulmonary venous flow allowed quantitative analysis in 92% patients (vs. 27% at baseline) and correlated well with peak velocities and velocity profiles obtained by transesophageal echocardiography (r = 0.91, p < 0.001). The enhanced color Doppler display of regurgitant jets increased jet area with a high interindividual variability (mean 276%), resulting in almost identical jet areas as unenhanced transesophageal values (r = 0.97, p < 0.001).
CONCLUSIONS
SHU 508A is a safe transpulmonary contrast agent that significantly enhances both spectral and color Doppler signals in the left heart. In specific patient subsets, the increase in signal-to-noise ratio improved the quantitative assessment of aortic stenosis, pulmonary venous flow and mitral regurgitation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.