1-Month Results From a Prospective Experience on CAS Using CGuard Stent System: The IRONGUARD 2 Study.

Sirignano Pasqualino, Stabile Eugenio, Mansour Wassim, Capoccia Laura, Faccenna Federico, Intrieri Francesco, Ferri Michelangelo, Saccà Salvatore, Sponza Massimo, Mortola Paolo, Ronchey Sonia, Grillo Placido, Chiappa Roberto, Losa Sergio, Setacci Francesco, Pirrelli Stefano, Taurino Maurizio, Ruffino Maria Antonella, Udini Marco, Palombo Domenico, Ippoliti Arnaldo, Montelione Nunzio, Setacci Carlo, de Donato Gianmarco, Ruggeri Massimo, Speziale Francesco

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study sought to evaluate 30-day safety and efficacy of dual-layer mesh-covered carotid stent systems for carotid artery stenting (CAS) in the clinical practice.

BACKGROUND

When compared with carotid endarterectomy, CAS has been associated with a higher rate of post procedural neurologic events; these could be related to plaque's debris prolapsing through stent's mesh. Consequently, the need for increased plaque coverage has resulted in the development of dual-layer mesh-covered carotid stent systems.

METHODS

From January 2017 to June 2019, a physician-initiated, prospective, multispecialty registry enrolled 733 consecutive patients undergoing CAS using the CGuard embolic prevention system in 20 centers. The primary endpoint was stroke up to 30 days; secondary endpoints were technical and procedural success; external carotid artery occlusion; and in-hospital and 30-day transient ischemic attack (TIA), acute myocardial infarction (AMI), and death rates.

RESULTS

Symptoms were present in 131 (17.87%) patients. An embolic protection device was used in 731 (99.72%) patients. Procedural success was 100%, technical success was obtained in all but 1 (99.86%) patient, who died in hospital due to a hemorrhagic stroke. Six TIAs, 2 minor strokes, and 1 AMI occurred during in-hospital stay, and external carotid artery occlusion was evident in 8 (1.09%) patients. Between hospital discharge and 30-day follow-up, 2 TIAs, 1 minor stroke, and 3 AMIs occurred. Therefore, the cumulative stroke rate was 0.54%.

CONCLUSIONS

This real-world registry suggests that use of CGuard embolic prevention system in clinical practice is safe and associated with a minimal occurrence of adverse neurological events up to 30-day follow-up.

Для цитирования: Sirignano Pasqualino, Stabile Eugenio, Mansour Wassim, Capoccia Laura, Faccenna Federico, Intrieri Francesco, Ferri Michelangelo, Saccà Salvatore, Sponza Massimo, Mortola Paolo, Ronchey Sonia, Grillo Placido, Chiappa Roberto, Losa Sergio, Setacci Francesco, Pirrelli Stefano, Taurino Maurizio, Ruffino Maria Antonella, Udini Marco, Palombo Domenico, Ippoliti Arnaldo, Montelione Nunzio, Setacci Carlo, de Donato Gianmarco, Ruggeri Massimo, Speziale Francesco. 1-Month Results From a Prospective Experience on CAS Using CGuard Stent System: The IRONGUARD 2 Study.. JACC. Cardiovascular interventions. 2020. DOI: 10.1016/j.jcin.2020.05.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.