MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.rehab.2022.101682

Медицинская библиотека · Annals of physical and rehabilitation medicine · 2022

Interstitial lung diseases specific measures in exercise interventions: A systematic review of measurement properties.

Oliveira Ana, Habash Razanne, Ellerton Lauren, Maybank Aline, Alsubheen Sanaa, Marques Alda, Goldstein Roger, Brooks Dina

Систематический обзорСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Effects of exercise-based interventions (EBIs) on people with interstitial lung disease (ILD) are not yet fully understood. Reasons may include the limited use of ILD-specific measures and/or the lack of adequate information regarding their measurement properties. The purpose of this review was to summarize the ILD-specific outcome measures used in EBI studies and their measurement properties.

METHODS

This was a two-phase systematic review: phase 1 identified ILD-specific measures used in EBI studies; phase 2 reviewed their measurement properties. PubMed, Web of Science, Scopus, EBSCO and EMBASE were searched up to March 2021. One reviewer extracted data, and 2 reviewers independently assessed studies risk of bias as well as the quality of measurement properties using the Consensus-Based Standards for the Selection of Health Status Measurement Instruments (COSMIN) recommendations.

RESULTS

Phase 1 identified 18 records. The St George's Respiratory Questionnaire for Interstitial Pulmonary Fibrosis (SGRQ-IPF) was the only ILD-specific outcome measure used (n = 2 trials). Phase 2 resulted in 31 eligible records; measurement properties were reported for 12 measures. Measures presented sufficient content validity, internal consistency (Cronbach's alpha 0.61-0.96), test-retest reliability (intraclass correlation coefficient 0.39; 0.96), hypothesis testing and responsiveness but were insufficient for measurement error and indeterminate for cross-cultural and structural validity. The outcome measures King's Brief Interstitial Lung Disease and SGRQ-IPF had higher evidence of adequate measurement properties than other measures. Quality of the evidence was mostly very low to moderate.

CONCLUSIONS

ILD-specific outcome measures are used infrequently in EBI trials, and there is scarce information regarding their measurement properties.

DATABASE REGISTRATION: CRD42018112466.

Для цитирования: Oliveira Ana, Habash Razanne, Ellerton Lauren, Maybank Aline, Alsubheen Sanaa, Marques Alda, Goldstein Roger, Brooks Dina. Interstitial lung diseases specific measures in exercise interventions: A systematic review of measurement properties.. Annals of physical and rehabilitation medicine. 2022. DOI: 10.1016/j.rehab.2022.101682.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.