MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/texcom/tgab066

Медицинская библиотека · Cerebral cortex communications · 2022

Stimulus-Induced Narrowband Gamma Oscillations are Test-Retest Reliable in Human EEG.

Kumar Wupadrasta Santosh, Manikandan Keerthana, Murty Dinavahi V P S, Ramesh Ranjini Garani, Purokayastha Simran, Javali Mahendra, Rao Naren Prahalada, Ray Supratim

СтатьяПеревод пока не подготовлен

Аннотация

Visual stimulus-induced gamma oscillations in electroencephalogram (EEG) recordings have been recently shown to be compromised in subjects with preclinical Alzheimer's Disease (AD), suggesting that gamma could be an inexpensive biomarker for AD diagnosis provided its characteristics remain consistent across multiple recordings. Previous magnetoencephalography studies in young subjects have reported consistent gamma power over recordings separated by a few weeks to months. Here, we assessed the consistency of stimulus-induced slow (20-35 Hz) and fast gamma (36-66 Hz) oscillations in subjects (n = 40) (age: 50-88 years) in EEG recordings separated by a year, and tested the consistency in the magnitude of gamma power, its temporal evolution and spectral profile. Gamma had distinct spectral/temporal characteristics across subjects, which remained consistent across recordings (average intraclass correlation of ~0.7). Alpha (8-12 Hz) and steady-state-visually evoked-potentials were also reliable. We further tested how EEG features can be used to identify 2 recordings as belonging to the same versus different subjects and found high classifier performance (AUC of ~0.89), with temporal evolution of slow gamma and spectral profile being most informative. These results suggest that EEG gamma oscillations are reliable across sessions separated over long durations and can also be a potential tool for subject identification.

Для цитирования: Kumar Wupadrasta Santosh, Manikandan Keerthana, Murty Dinavahi V P S, Ramesh Ranjini Garani, Purokayastha Simran, Javali Mahendra, Rao Naren Prahalada, Ray Supratim. Stimulus-Induced Narrowband Gamma Oscillations are Test-Retest Reliable in Human EEG.. Cerebral cortex communications. 2022. DOI: 10.1093/texcom/tgab066.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.