DOI 10.1016/j.ijcha.2020.100517
Impact of type and size of annuloplasty prosthesis on hemodynamic status after mitral valve repair for degenerative disease.
Аннотация
OBJECTIVE
The aim of this study is to evaluate mitral valve hemodynamics after mitral valve repair for degenerative disease, and seek the impact of type/size of annuloplasty prosthesis on resting cardiac hemodynamics.
METHODS
Between October 2012 and June 2019, 301 patients underwent isolated mitral valve repair for degenerative disease were enrolled. Correlation between postoperative mitral hemodynamics and type/size of annuloplasty prosthesis was evaluated.
RESULTS
There were significant correlations between annuloplasty size and peak velocity (r = -0.41, p < 0.001), peak transmitral pressure gradient (TMPG) (r = -0.40, p < 0.001), mean TMPG (r = -0.41, p < 0.001), effective orifice area (EOA) (r = 0.26, p < 0.001), and pulmonary artery systolic pressure (r = -0.15, p = 0.010). In patients with larger annuloplasty prostheses (≥30 mm), the type of annuloplasty prosthesis (band or ring) did not influence the mitral hemodynamics, however, mean TMPG was significantly greater in patients with a full ring (2.9 mmHg [2.1-3.7] vs. 4.0 mmHg [2.8-5.0], p < 0.001) in patients with smaller annuloplasty (<30 mm). Left ventricular ejection fraction and stroke volume were significantly associated with an increase of TMPG (r = 0.14, p = 0.016 and r = 0.24, p < 0.001).
CONCLUSIONS
A larger partial band had the potential to improve mitral hemodynamics after mitral repair for degenerative disease. However, echocardiographic mitral hemodynamics was influenced by LV function. Therefore, a more accurate method is required to elucidate the true impact of mitral repair on hemodynamics.