Медицинская библиотека · Echocardiography (Mount Kisco, N.Y.) · 2019

Correlation and agreement between 2D and 3D speckle-tracking echocardiography for left ventricular volumetric, strain, and rotational parameters in healthy volunteers and in patients with mild mitral stenosis.

Poyraz Esra, Kemaloglu Oz Tugba, Çetin Güvenç Rengin, Guvenc Tolga Sinan

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Recent advances had allowed measurement of myocardial deformation parameters using 3D speckle-tracking echocardiography (STE). Agreement between these two modalities and interchangeability of findings remain as an issue since 2DSTE is more widely available than 3DSTE. The aim of this study was to investigate the correlation and agreement between 2DSTE and 3DSTE in healthy volunteers and in patients with mild mitral stenosis (MS).

METHODS

Data from 31 patients with mild MS and 27 healthy volunteers were included in this study. Data were analyzed for the correlation and agreement between 2DSTE and 3DSTE for volumetric, strain, and rotational parameters.

RESULTS

There were no significant differences between 2DSTE and 3DSTE in both control and MS groups for left ventricular volumetric and rotational parameters. 3D global longitudinal strain (GLS) and global circumferential strain (GCS) were significantly higher in healthy volunteers (P < 0.001 for both), while only 3DGCS was significantly higher than 2DGCS in MS group (P < 0.001). The correlation between 3DSTE and 2DSTE was weak-to-moderate in both groups for strain and rotational parameters, and overall, correlation coefficients were higher in MS group. An exception was GLS in MS group, where coefficient of correlation was excellent (r = 0.907). Agreement between two modalities was poor for strain and rotational parameters, and the average bias was high.

CONCLUSIONS

Overall, the agreement between 2DSTE and 3DSTE for strain and rotational measures was poor with a high average bias. The agreement between 2DSTE and 3DSTE is affected by the presence of underlying MS and the direction of strain.

Для цитирования: Poyraz Esra, Kemaloglu Oz Tugba, Çetin Güvenç Rengin, Guvenc Tolga Sinan. Correlation and agreement between 2D and 3D speckle-tracking echocardiography for left ventricular volumetric, strain, and rotational parameters in healthy volunteers and in patients with mild mitral stenosis.. Echocardiography (Mount Kisco, N.Y.). 2019. DOI: 10.1111/echo.14336.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.