MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4321/s0365-66912004000700005

Медицинская библиотека · Archivos de la Sociedad Espanola de Oftalmologia · 2004

[Transcanalicular dacryocystorhinostomy technique using diode laser].

Alañón Fernández F J, Alañón Fernández M A, Martínez Fernández A, Cárdenas Lara M

Клиническое исследованиеАннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To describe the surgical technique and to evaluate the clinical results of carrying out transcanalicular dacryocystorhinostomies using a diode laser (DCR-TC), including the advantages and limitations of this technique.

METHODS

43 DCR-TC were studied and they were analysed using a prospective, interventional, non randomized and non comparative study. We used local and topical anaesthesia in patients with a clinical history of epiphora or dacryocystitis for nasolacrimal obstruction. A diode laser was used to effect a vaporization of the lacrimal sac, osteotomy and vaporization with coagulation of nasal mucosa. The mean duration of surgery was 14 minutes (range 7 to 29 minutes). In all cases, and during a two-month period, bicanalicular intubation was carried out using a silicone tube and prolene filament. Follow-up was between 4 to 38 months. The degree of epiphora was evaluated using the Munk scale and lacrimal permeability was evaluated using Jones I and II tests by direct videoendoscopic control in all cases.

RESULTS

43 DCR-TC were realized, 39 cases are asymptomatic (90.7%). 2 of them (4.65%) had epiphora (degree 2 on the Munk scale) and permeable tract. One case (2.32%) presented lower canaliculi obstruction. One patient showed total osteotomy closing.

CONCLUSIONS

Transcanalicular dacryocystorhinostomy carried out using a diode laser is a useful method because it does not cause cutaneous scarring, it hardly produces pain and bleeding, it respects the lacrimal pump, it needs less surgical time, it can be carried out in an out-patient surgery and it generates minimal intra and postsurgical morbility.

Для цитирования: Alañón Fernández F J, Alañón Fernández M A, Martínez Fernández A, Cárdenas Lara M. [Transcanalicular dacryocystorhinostomy technique using diode laser].. Archivos de la Sociedad Espanola de Oftalmologia. 2004. DOI: 10.4321/s0365-66912004000700005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.