A different concept in the application of dacryoscintigraphy.

Zincirkeser S, Celen Y Z

Клиническое исследованиеКонтролируемое клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Current dacryoscintigraphy methods have several potential pitfalls, the most important of which is the outflow of tears. Another is the difficulty in fixing the head with the patient seated. To overcome these difficulties, a new method was applied.

MATERIALS AND

METHODS

The study included 77 persons: 43 controls and 34 patients with epiphora. Two methods were applied to the two groups. In the first, protocol 1 (the current conventional protocol), the patient was seated in front of a gamma camera and one drop (50 microl) Tc-99m pertechnetate containing 50 to 100 microCi radioactivity was instilled in the inferior fornix or outer canthus of the eye and dynamic and static images were obtained for approximately 15 to 20 minutes. In the other, protocol 2 (our protocol), 100 microCi (10 microl) Tc-99m pertechnetate was instilled in the outer canthus of the eye using a micropipette with the patient in the supine position under the gamma camera. Dynamic images were taken for only 5 minutes.

CONCLUSION

The pitfalls and difficulties seen with protocol 1 were lessened to a great degree in protocol 2.

Для цитирования: Zincirkeser S, Celen Y Z. A different concept in the application of dacryoscintigraphy.. Clinical nuclear medicine. 2001. DOI: 10.1097/00003072-200109000-00008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.