MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00784-020-03416-z

Медицинская библиотека · Clinical oral investigations · 2020

Crestal bone loss due to abutment manipulation and an internal silver deposition implant design in a canine model.

Fickl Stefan, Stappert Christian F J, Kohles Sean S

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The study aimed to evaluate the effect of internal silver coating as a countermeasure to crestal bone loss around implants with or without multiple abutment disconnections/reconnections.

MATERIALS AND

METHODS

Following tooth extraction, 48 implants with connected healing abutments (24 implants internally coated with elemental silver) were placed in the mandible of eight beagle dogs. Two months after implant surgery one side of the mandible was randomly assigned to four abutment manipulations (disconnection/reconnection) on a weekly basis. At 4 months postoperative, biopsies were obtained and prepared for histomorphometric analysis.

RESULTS

Healing abutment manipulation increased crestal bone remodeling when compared to no abutment manipulation (1.28 mm versus 0.92 mm, respectively), although the difference was not statistically significant (p = 0.0836). Overall, an internal silver coating did not provide a statistically sufficient implant treatment characteristic as a countermeasure to crestal bone loss (p = 0.7801).

CONCLUSIONS

These findings indicate that the controlled variables explored here (abutment manipulation/internal silver coating) have a limited effect on initial crestal bone loss.

CLINICAL RELEVANCE: Abutment manipulation during prosthetic work does not seem to harm the peri-implant soft and hard tissues.

Для цитирования: Fickl Stefan, Stappert Christian F J, Kohles Sean S. Crestal bone loss due to abutment manipulation and an internal silver deposition implant design in a canine model.. Clinical oral investigations. 2020. DOI: 10.1007/s00784-020-03416-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.