m+Medelevator.RU
← Поиск публикаций
Minerva dental and oral science · 2020

Effect of neutralization and hydrofluoric acid precipitate remotion on the compressive strength of monolithic lithium disilicate crowns.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zogheib Lucas V, Lopes Guilherme R, Matos Jefferson D, Castro Daniel S, Bottino Marco A, McCabe John, Kimpara Estevão T

Аннотация

BACKGROUND: The cleaning protocol for the ceramic surface after acid etching resulted in a decrease in bond strength and flexural strength of a glass ceramic. This study aims to evaluate the effect of different ceramic surface treatments after hydrofluoric acid etching (HF) on the compressive strength of monolithic lithium disilicate crowns.

METHODS: Forty (40) human third molars received conventional full coverage preparation. After performing digital impressions of teeth preparations, ceramic blocks were machined using a CAD/CAM system in order to obtain the crowns. The crowns were distributed in 4 groups as ceramic surface treatment (N.=10): (HF) - 4.9% HF for 20s + air-water spray for 30s; (HFN) - HF + neutralizing agent for 5 min (N); (HFU) - HF + ultrasonic bath for 5 min (U); e (HFNU) - HF + N + U. SEM and EDS analysis was performed in each group in order to characterize the ceramic surface and to verify the chemical element distribution after HF cleaning protocols. A silane layer was applied (for 60s), and crowns were then cemented with dual resin cement. A compressive load was applied on the middle of the occlusal crown surface with a crosshead speed of 1 mm/min until fracture. Data were analyzed using ANOVA and Tukey test (α=0.05).

RESULTS: Fluoride ions were found in samples of all postetching cleaning protocols. The mean value (Kgf) was: HF =169.92±21.37; HFN =187.34±34.79; HFU =166.63±40.22 and HFNU=175.26±40.22. The ceramic surface treatment after HF etching did not significantly influence (P>0.05) the compressive strength of the tested ceramic crowns.

CONCLUSIONS: Surface treatments with neutralizing agent associated with the ultrasonic bath as the pre-cementation protocol was the most efficient protocol in eliminating the precipitate deposited on the porosities created by acid etching.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты