Safety and complications associated with the use of protamine in percutaneous coronary intervention.

Alrayes Hussayn, Alsaadi Ayman, Alkhatib Ahmad, Patel Dhruvil Ashishkumar, Alqarqaz Mohammad, Frisoli Tiberio, Fuller Brittany, Khandelwal Akshay, Koenig Gerald, O'Neill Brian P, Villablanca Pedro, Zaidan Mohammad, O'Neill William, Alaswad Khaldoon, Basir Mir

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

There is a paucity of data on the use of protamine after PCI. The purpose of this study was to assess the incidence of thrombotic complications of protamine after high-risk PCI.

METHODS

The authors conducted a retrospective analysis of 168 patients. All patients received protamine intra- or immediately post-index PCI. Baseline characteristics and procedural characteristics including heparin dosing, protamine dosing, and bleeding and thrombotic complications were evaluated. The primary outcome was the incidence of acute stent thrombosis (ST), subacute ST, and 'other' thrombotic complications. Secondary outcomes included mortality within 24 hours and within 30 days of the index procedure.

RESULTS

A total of 168 patients were included. The majority of patients received dual anti-platelet therapy prior to the index procedure (85%). The average procedure time was 202 ± 103 minutes, and an average of 2.59 (± 1.38) stents were deployed. An average protamine dose of 32mg was administered, and the median dose was 20mg (IQR 20). Seventy-three (43%) had a coronary perforation and five (3%) had access site related bleeding requiring transfusion. Four (2%) patients had acute ST, no patients experienced subacute ST, and 2 (1%) patients developed non-coronary arterial thrombosis. Eight (5%) died within 24 hours of their PCI and 14 (8%) patients died within 30 days after PCI.

CONCLUSIONS

In our cohort, administration of protamine was well tolerated in the majority of patients, however, 3.6% of patients did experience coronary or peripheral arterial thrombosis warranting caution when using protamine in these challenging scenarios.

Для цитирования: Alrayes Hussayn, Alsaadi Ayman, Alkhatib Ahmad, Patel Dhruvil Ashishkumar, Alqarqaz Mohammad, Frisoli Tiberio, Fuller Brittany, Khandelwal Akshay, Koenig Gerald, O'Neill Brian P, Villablanca Pedro, Zaidan Mohammad, O'Neill William, Alaswad Khaldoon, Basir Mir. Safety and complications associated with the use of protamine in percutaneous coronary intervention.. The Journal of invasive cardiology. 2025. DOI: 10.25270/jic/24.00336.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.