MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ogla.2021.10.013

Медицинская библиотека · Ophthalmology. Glaucoma · 2021

Multivariate Normative Comparison, a Novel Method for Improved Use of Retinal Nerve Fiber Layer Thickness to Detect Early Glaucoma.

Chua Jacqueline, Schwarzhans Florian, Wong Damon, Li Chi, Husain Rahat, Crowston Jonathan G, Perera Shamira A, Sng Chelvin C A, Nongpiur Monisha E, Majithia Shivani, Tham Yih Chung, Thakur Sahil, Da Soh Zhi, Cheng Ching-Yu, Aung Tin, Fischer Georg, Vass Clemens, Schmetterer Leopold

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Detection of early glaucoma remains limited with the conventional analysis of the retinal nerve fiber layer (RNFL). This study assessed whether compensating the RNFL thickness for multiple demographic and anatomic factors improves the detection of glaucoma.

DESIGN

Cross-sectional study.

PARTICIPANTS

Three hundred eighty-seven patients with glaucoma and 2699 healthy participants.

METHODS

Two thousand six hundred ninety-nine healthy participants were enrolled to construct and test a multivariate compensation model, which then was applied in 387 healthy participants and 387 patients with glaucoma (early glaucoma, n = 219; moderate glaucoma, n = 97; and advanced glaucoma, n = 71). Participants underwent Cirrus spectral-domain OCT (Carl Zeiss Meditec) imaging of the optic disc and macular cubes. Compensated RNFL thickness was generated based on ethnicity, age, refractive error, optic disc (ratio, orientation, and area), fovea (distance and angle), and retinal vessel density. The RNFL thickness measurements and their corresponding areas under the receiver operating characteristic curve (AUCs) were obtained.

MAIN OUTCOME AND MEASURES: Measured and compensated RNFL thickness measurements.

RESULTS

After applying the Asian-specific compensation model, the standard deviation of RNFL thickness reduced, where the effect was greatest for Chinese participants (16.9%), followed by Malay participants (13.9%), and Indian participants (12.1%). Multivariate normative comparison outperformed measured RNFL for discrimination of early glaucoma (AUC, 0.90 vs. 0.85; P < 0.001), moderate glaucoma (AUC, 0.94 vs. 0.91; P < 0.001), and advanced glaucoma (AUC, 0.98 vs. 0.96; P < 0.001).

CONCLUSIONS

The multivariate normative database of RNFL showed better glaucoma discrimination capability than conventional age-matched comparisons, suggesting that accounting for demographic and anatomic variance in RNFL thickness may have usefulness in improving glaucoma detection.

Для цитирования: Chua Jacqueline, Schwarzhans Florian, Wong Damon, Li Chi, Husain Rahat, Crowston Jonathan G, Perera Shamira A, Sng Chelvin C A, Nongpiur Monisha E, Majithia Shivani, Tham Yih Chung, Thakur Sahil, Da Soh Zhi, Cheng Ching-Yu, Aung Tin, Fischer Georg, Vass Clemens, Schmetterer Leopold. Multivariate Normative Comparison, a Novel Method for Improved Use of Retinal Nerve Fiber Layer Thickness to Detect Early Glaucoma.. Ophthalmology. Glaucoma. 2021. DOI: 10.1016/j.ogla.2021.10.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.