OBJECTIVES

To evaluate whether etonogestrel concentrations are reduced to a level that could potentially reduce contraceptive efficacy when the etonogestrel contraceptive implant is used concomitantly with dolutegravir-based antiretroviral therapy (ART).

STUDY

DESIGN

We conducted a non-randomized, open-label, cross-sectional pharmacokinetic study among women using single-rod etonogestrel contraceptive implants in Botswana. We compared plasma etonogestrel concentrations, sampled at a single time-point between 3 and 12 months from implant insertion, among implant users living with HIV and receiving dolutegravir-based ART with HIV-negative implant users. We also assessed concentrations among implant users living with HIV and receiving efavirenz-based ART. We compared geometric mean etonogestrel concentrations analyzing data from 142 participants: 97 HIV-negative, 30 using dolutegravir, and 15 using efavirenz.

RESULTS

The groups were similar. Duration of implant use was between 3 and 12 months (median = 5). Geometric mean etonogestrel plasma concentrations and 90% confidence intervals of the mean were 227.5(212.4-243.8), 289.6(251.8-333.0) and 76.4(63.9-91.4) pg/mL among the HIV-negative, dolutegravir- and efavirenz-based ART groups, respectively. All women in the HIV-negative and dolutegravir-based ART groups had etonogestrel concentrations above 90 pg/mL; 9/15 women (60%) using efavirenz-based ART had concentrations below 90 pg/mL. On average, etonogestrel levels were lower among individuals who had implants inserted for longer durations.

CONCLUSIONS

Implant users receiving dolutegravir-based ART had a higher mean etonogestrel concentration compared to HIV-negative women, and none had etonogestrel concentrations below the posited threshold for ovulation suppression. In contrast, women in the efavirenz-group had much lower etonogestrel concentrations. Overall, these data provide evidence that the etonogestrel implant may be effectively combined with dolutegravir-based ART regimens.

IMPLICATIONS: The etonogestrel implant remains a highly effective contraceptive option for women living with HIV who use dolutegravir-based ART.

Для цитирования: Bishop Ian J, Gertz Alida M, Simon Boikhutso, Tawe Leabaneng, Lechiile Kwana, Liu Serena, Teodoro Nicholas, Mussa Aamirah, Avalos Ava, Malima Sifelani, Maotwe Tshego, Mokganya Lesego, Westhoff Carolyn L, Morroni Chelsea. Etonogestrel concentrations among contraceptive implant users in Botswana using and not using dolutegravir-based antiretroviral therapy.. Contraception. 2020. DOI: 10.1016/j.contraception.2020.04.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.