DOI 10.1097/j.jcrs.0000000000001066

Медицинская библиотека · Journal of cataract and refractive surgery · 2023

Corneal ectasia detection by epithelial pattern standard deviation from OCT.

Salomão Marcella Q, Hofling-Lima Ana Luisa, Gomes Esporcatte Louise Pellegrino, Correa Fernando Faria, Meneses Erica Ferreira, Li Yan, Huang David, Lopes Bernardo, Sena Nelson, Machado Aydano P, Ambrósio Renato

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To test the ability of the corneal epithelial pattern standard deviation (PSD) to distinguish between normal and cases with corneal ectatic condition.

SETTING

Instituto de Olhos Renato Ambrósio, Rio de Janeiro, Brazil.

DESIGN

Cross-sectional retrospective study.

METHODS

Patients were stratified into 4 groups based on clinical data and corneal tomography. Groups 1 and 2 comprised 1 eye randomly selected from 105 patients with normal corneas (N) and 86 patients with bilateral keratoconus (KC). Groups 3 and 4, respectively, comprised 11 ectatic eyes with no surgical treatment for KC (very asymmetric ectasia [VAE]-E) from patients whose fellow eyes (61) presented with normal topographic patterns (VAE-NT). Corneas were scanned using an OCT system (RT Vue) and Scheimpflug corneal tomography (Pentacam) and also had biomechanical assessment through the Corvis ST. Corneal epithelial thickness maps were analyzed, and the PSD value was calculated. The area under the receiver operating characteristic curve analysis was used to evaluate the diagnostic accuracy of the indices.

RESULTS

A total of 105 normal eyes, 86 keratoconic eyes, and 11 ectatic eyes whose fellow eyes (61) presented normal topographic patterns were evaluated. Epithelial PSD was significantly different across the 4 groups ( P < .0001). The pairwise comparison revealed that the normal group presented significantly lower values than both ectasia groups (KC and VAE-E, P < .0001) and the VAE-NT group ( P = .0008). There was no statistical significant difference between KC and VAE-E ( P = .4284), while they were significantly higher than the VAE-NT group ( P < .0001 and P = .0004).

CONCLUSIONS

Epithelial PSD can be used to detect abnormal epithelial thickness patterns. Corneal epithelial thickness changes could be detected accurately in patients with KC, even in the form fruste of the disease.

Для цитирования: Salomão Marcella Q, Hofling-Lima Ana Luisa, Gomes Esporcatte Louise Pellegrino, Correa Fernando Faria, Meneses Erica Ferreira, Li Yan, Huang David, Lopes Bernardo, Sena Nelson, Machado Aydano P, Ambrósio Renato. Corneal ectasia detection by epithelial pattern standard deviation from OCT.. Journal of cataract and refractive surgery. 2023. DOI: 10.1097/j.jcrs.0000000000001066.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.