Cornea · 2022
Meniscus-Shaped Stromal Lenticule Addition Keratoplasty for Corneal Regularization and Thickening in Advanced Keratoconus.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Pedrotti Emilio, Bonacci Erika, Fasolo Adriano, Fraccaroli Sebastiano, Anastasi Marco, Vinciguerra Riccardo, Vinciguerra Paolo, Giorgio Marchini
Аннотация
PURPOSE: The aim of this study was to investigate the outcome of the meniscus-shaped stromal lenticule addition keratoplasty (MS-SLAK) in corneal regularization and thickness.
METHODS: Patients waiting for deep anterior lamellar keratoplasty for advanced keratoconus with an intolerance to contact lenses (CLs) underwent the MS-SLAK procedure by FSL 80 kHz ablation (VICTUS, Technolas Perfect Vision, DE). Customized positive meniscus-shaped stromal lenticules were obtained and implanted. Examination was performed at baseline and at 3-, 6-, and 12-month follow-up and included corrected distance visual acuity both with spectacles and CLs (spectacle CDVA and CL-CDVA), manifest refraction spherical equivalent, slit-lamp examination, anterior segment optical coherence tomography, corneal topography, and in vivo confocal microscopy.
RESULTS: Fifteen patients completed the study. Statistical increases in corneal thickness values were found from the first follow-up ( P < 0.001). Improvement in the Surface Asymmetry Index ( P = 0.04), Symmetry Index ( P = 0.02), spherical aberration ( P < 0.001), coma ( P = 0.18), high-order aberration ( P = 0.37), and anterior asphericity index (Q) ( P = 0.31) were found at 12 months. At the 12-month follow-up, no improvement were found in spectacle CDVA ( P = 0.23); however, all patients reported CL wearing tolerance recovery, and significant improvement in CL-CDVA ( P = 0.002) was found. The confocal microscopy at 12 months showed a significant increase in keratocyte density within the lenticule and absence of fibrotic reactions in both anterior and posterior interfaces.
CONCLUSIONS: MS-SLAK seems to be effective in regularizing the corneal surface as showed by the significant improvement in topographic symmetry indices, coma, and high-order aberration. The corneal regularization is also confirmed by the results in anterior Q and the recovery of the CL wearing tolerance.
METHODS: Patients waiting for deep anterior lamellar keratoplasty for advanced keratoconus with an intolerance to contact lenses (CLs) underwent the MS-SLAK procedure by FSL 80 kHz ablation (VICTUS, Technolas Perfect Vision, DE). Customized positive meniscus-shaped stromal lenticules were obtained and implanted. Examination was performed at baseline and at 3-, 6-, and 12-month follow-up and included corrected distance visual acuity both with spectacles and CLs (spectacle CDVA and CL-CDVA), manifest refraction spherical equivalent, slit-lamp examination, anterior segment optical coherence tomography, corneal topography, and in vivo confocal microscopy.
RESULTS: Fifteen patients completed the study. Statistical increases in corneal thickness values were found from the first follow-up ( P < 0.001). Improvement in the Surface Asymmetry Index ( P = 0.04), Symmetry Index ( P = 0.02), spherical aberration ( P < 0.001), coma ( P = 0.18), high-order aberration ( P = 0.37), and anterior asphericity index (Q) ( P = 0.31) were found at 12 months. At the 12-month follow-up, no improvement were found in spectacle CDVA ( P = 0.23); however, all patients reported CL wearing tolerance recovery, and significant improvement in CL-CDVA ( P = 0.002) was found. The confocal microscopy at 12 months showed a significant increase in keratocyte density within the lenticule and absence of fibrotic reactions in both anterior and posterior interfaces.
CONCLUSIONS: MS-SLAK seems to be effective in regularizing the corneal surface as showed by the significant improvement in topographic symmetry indices, coma, and high-order aberration. The corneal regularization is also confirmed by the results in anterior Q and the recovery of the CL wearing tolerance.