MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-022-02533-w

Медицинская библиотека · International ophthalmology · 2022

Best indices of dual Scheimpflug/Placido tomographer for keratoconus detection.

Heidari Zahra, Jafarzadehpour Ebrahim, Mohammadpour Mehrdad, Hashemi Hassan

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the accuracy of different corneal parameters in detecting keratoconus using a dual Scheimpflug/Placido system (Sirius, CSO, Italy).

METHODS

Sixty-eight eyes of 68 keratoconus patients and 77 eyes of 77 normal subjects were prospectively assessed in a diagnostic test study. The mean differences of the corneal parameters were compared using the independent t-test. The accuracy of curvature, elevation, pachymetry, and aberrometry indices, aqueous depth, and corneal volume in 10 mm was evaluated using the area under the curve (AUC), and the DeLong method was used for the comparison of AUCs. Multiple tests in a parallel manner and multiple logistic regression analysis were applied to determine the best predictor indices.

RESULTS

All indices except aqueous depth and corneal volume were significantly different between the two groups (P < 0.001). Back keratoconus vertex (KVb) and front Baiocchi-Calossi-Versaci index (BCVf) had the highest sensitivity (for both 98.53%) followed by front symmetry index (SIf) (96.12%) and thinnest point of the cornea (88.24%) in elevation, aberrometry, curvature, and pachymetry parameters, respectively. The highest diagnostic ability was observed in KVb (AUC 0.993) and BCVf index (AUC 0.992) (DeLong > 0.05). Multiple test analysis showed a combination of indices with the highest accuracy that was similar to the performance of each one individually, and keratoconus was diagnosed correctly in 98.5% of the cases (R2 = 93%).

CONCLUSION

The parameters extracted from Sirius can differentiate keratoconus from normal corneas with high accuracy without the need for complex computational algorithms. Elevation-based and combined aberrometry indices had the highest diagnostic power.

Для цитирования: Heidari Zahra, Jafarzadehpour Ebrahim, Mohammadpour Mehrdad, Hashemi Hassan. Best indices of dual Scheimpflug/Placido tomographer for keratoconus detection.. International ophthalmology. 2022. DOI: 10.1007/s10792-022-02533-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.