The Journal of international medical research · 2022
Correlation between corneal dynamic responses and keratoconus topographic parameters.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Tai Hsi-Yun, Lin Jun-Ji, Huang Yi-Hung, Shih Po-Jen, Wang I-Jong, Yen Jia-Yush
Аннотация
OBJECTIVE: To investigate the correlation between corneal biomechanical properties and topographic parameters using machine learning networks for automatic severity diagnosis and reference benchmark construction.
METHODS: This was a retrospective study involving 31 eyes from 31 patients with keratonus. Two clustering approaches were used (i.e., shape-based and feature-based). The shape-based method used a keratoconus benchmark validated for indicating the severity of keratoconus. The feature-based method extracted imperative features for clustering analysis.
RESULTS: There were strong correlations between the symmetric modes and the keratoconus severity and between the asymmetric modes and the location of the weak centroid. The Pearson product-moment correlation coefficient (PPMC) between the symmetric mode and normality was 0.92 and between the asymmetric mode and the weak centroid value was 0.75.
CONCLUSION: This study confirmed that there is a relationship between the keratoconus signs obtained from topography and the corneal dynamic behaviour captured by the Corvis ST device. Further studies are required to gather more patient data to establish a more extensive database for validation.
METHODS: This was a retrospective study involving 31 eyes from 31 patients with keratonus. Two clustering approaches were used (i.e., shape-based and feature-based). The shape-based method used a keratoconus benchmark validated for indicating the severity of keratoconus. The feature-based method extracted imperative features for clustering analysis.
RESULTS: There were strong correlations between the symmetric modes and the keratoconus severity and between the asymmetric modes and the location of the weak centroid. The Pearson product-moment correlation coefficient (PPMC) between the symmetric mode and normality was 0.92 and between the asymmetric mode and the weak centroid value was 0.75.
CONCLUSION: This study confirmed that there is a relationship between the keratoconus signs obtained from topography and the corneal dynamic behaviour captured by the Corvis ST device. Further studies are required to gather more patient data to establish a more extensive database for validation.