Evaluation of macular function and morphology following accelerated collagen cross-linking in progressive keratoconus.
Аннотация
PURPOSE: To assess any changes in macular function and morphology in patients with progressive keratoconus undergoing accelerated corneal cross-linking (CXL).
METHODS
This prospective case series included 9 eyes of 8 patients with progressive keratoconus undergoing CXL using a high intensity accelerated protocol (9 mW/cm2 for 14 min) with a total surface dose of 7.5 J/cm2. Visual acuity assessment, slit lamp biomicroscopy, dilated fundoscopy, corneal tomography, multifocal electroretinography (mfERG) and spectral domain optical coherence tomography scan were performed at baseline, 2 weeks and 6 weeks postoperatively.
RESULTS
Uncorrected and corrected distance visual acuity did not change significantly at 2 weeks and 6 weeks following accelerated CXL compared to baseline. Retinal response density (RRD) of mfERG significantly decreased at 2 weeks postoperatively compared to baseline (p = 0.008) but did not differ from the baseline value at 6 weeks postoperatively in the fovea (ring 1) (p = 0.95). Similarly, P1 latency significantly decreased at 2 weeks (p = 0.04) but did not change at 6 weeks (p = 1.00) postoperatively compared to baseline in the fovea. No changes in RRD or P1 latency were observed in the retinal rings surrounding the fovea (rings 2 to 5). Central foveal thickness did not change at 2 weeks and 6 weeks postoperatively compared to baseline (p = 0.53 and p = 0.93, respectively).
CONCLUSIONS
A short-term reversible decrease in macular electrical activity without any structural changes seems to occur after accelerated CXL in patients with progressive keratoconus. The return of macular response to the preoperative values shows the safety of the CXL protocol.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.