Corneal Response to Scleral Contact Lens Wear in Keratoconus.

Cagliari Cristina, Schor Paulo, Formentin Luiz, Lipener César, Dos Santos Myrna Serapião, Oliveira Helena, Raulino Junior José Ney de Carvalho, de Freitas Denise

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To verify corneal alterations in patients with keratoconus who wear scleral contact lenses (ScCLs), focusing on corneal endothelial assessment.

METHODS

Scleral contact lenses were fitted in 22 patients with keratoconus. During a 90-day follow-up, patients were assessed in three visits: at baseline, after 30 days, and after 90 days. Patients underwent visual acuity measurement, slitlamp biomicroscopy of the anterior segment, specular microscopy of the corneal endothelium, corneal pachymetry, measurement of the clearance between the cornea and the lens, and follow-up of ectasia.

RESULTS

Variables related to endothelial morphology and pachymetry values did not change significantly over time. Central clearance measurements decreased in the 90-day period. No progression of corneal ectasia was observed, neither were infectious or inflammatory processes in the same period.

CONCLUSION

Daily wear of ScCLs in patients with keratoconus was not associated with adverse effects on the cornea or endothelium over a period of 90 days nor was there evidence of disease progression. Central clearance values diminished over that period, but the significance of this observation remains unclear.

Для цитирования: Cagliari Cristina, Schor Paulo, Formentin Luiz, Lipener César, Dos Santos Myrna Serapião, Oliveira Helena, Raulino Junior José Ney de Carvalho, de Freitas Denise. Corneal Response to Scleral Contact Lens Wear in Keratoconus.. Eye & contact lens. 2022. DOI: 10.1097/icl.0000000000000899.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.