MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/02713683.2022.2058020

Медицинская библиотека · Current eye research · 2022

In Vivo Biomechanical Changes Associated With Keratoconus Progression.

Padmanabhan Prema, Lopes Bernardo T, Eliasy Ashkan, Abass Ahmed, Elsheikh Ahmed

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To assess the biomechanical deterioration arising from keratoconus progression in-vivo.

METHODS

The preoperative examinations of 32 progressive KC cases that were submitted to corneal cross-linking were evaluated. The examinations included the corneal tomography using the Pentacam HR and biomechanical parameters assessed by the Corvis ST (Oculus, Wetzlar, Germany). The results were recorded at two time points, the latter of which was at the last visit before the CXL procedure. Keratoconus progression was characterised by a significant change in the ABCD system.

RESULTS

At the last follow-up visit (41.4 ± 40.9 months) all morphological parameters of the ABCD grading system showed significant deterioration (p < 0.001). The comparative analyses revealed a significant reduction in corneal stiffness expressed by a significant reduction in the stress-strain index (SSI: -0.10 ± 0.06, p < 0.001), the Stiffness parameter A1 (SP-A1: -6.1 ± 12.0 mmHg/mm, p = 0.011), by a significant increase in the integrated Inverse Radius (IIR: 0.95 ± 1.04 mm-1, p < 0.001) and in the deflection amplitude (DA) ratio (0.23 ± 0.58, p = 0.034). A barely significant increase in the DA also pointed towards corneal stiffness reduction. (0.04 ± 0.13 mm, p = 0.056). The SSI and the IIR were the indices with the smallest overlaps between the two examinations.

CONCLUSIONS

It has been demonstrated in-vivo that corneal biomechanical deterioration occurs with keratoconus progression. The larger changes observed in the SSI and the IIR when compared to the remaining biomechanical parameters suggests that these parameters could be suitable to assess the corneal stiffness reduction in keratoconus natural progression.

Для цитирования: Padmanabhan Prema, Lopes Bernardo T, Eliasy Ashkan, Abass Ahmed, Elsheikh Ahmed. In Vivo Biomechanical Changes Associated With Keratoconus Progression.. Current eye research. 2022. DOI: 10.1080/02713683.2022.2058020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.