MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-022-02255-z

Медицинская библиотека · International ophthalmology · 2022

Validation of the multi-metric D-index change in the assessment of keratoconus progression.

Achiron Asaf, Yavnieli Roy, Olshaker Hagar, Levinger Eliya, Tuuminen Raimo, Livny Eitan, Elbaz Uri, Bahar Irit, Nahum Yoav

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To validate the effectiveness of the multi-metric D-index by Pentacam in detecting keratoconus (KC) progression.

MATERIALS AND

METHODS

This was a retrospective study of KC patients at the Rabin Medical Center, Petah Tikva, Israel, during 2016-2018 with at least two corneal tomography examinations six months apart. Agreement between clinical diagnosis of progression (1.5D increase in mean keratometric value, 1D increase in Kmax, a 5% decrease in central corneal thickness (CCT), worsening of visual acuity by more than one line, or deterioration of manifest corneal astigmatism > 1.5D) and the D-index was evaluated. Receiver operating characteristic (ROC) analysis was used to find the D-index's optimal cutoff value to show progression.

RESULTS

We included KC eyes in the stable group (N = 7) and the progression group (N = 54). Patient demographics and tomographic parameters at baseline were similar between the groups. The D-index change was significantly higher in the progression group than in the stable group (median + 1 and 0.0, respectively, p = 0.024). Based on the ROC analysis, the optimal D-index cutoff change within at least six months was 0.32 (59.3% sensitivity and 100% specificity (area under the curve [AUC] = 0.771, Youden = 0.592). Subjects with a D-index change above this value had a 21.1-fold increase in odds for corneal ectasia progression requiring CXL (OR: 21.1, 95%CI 1.17-398.8, p = 0.038).

CONCLUSION

The multi-metric D-index can serve as a clinically feasible parameter to detect KC progression and guide patients' referral for further interventions.

Для цитирования: Achiron Asaf, Yavnieli Roy, Olshaker Hagar, Levinger Eliya, Tuuminen Raimo, Livny Eitan, Elbaz Uri, Bahar Irit, Nahum Yoav. Validation of the multi-metric D-index change in the assessment of keratoconus progression.. International ophthalmology. 2022. DOI: 10.1007/s10792-022-02255-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.