Аннотация

PURPOSE: To simplify the fitting process, this study was designed to predict the initial power of contact lenses using the regression model based on manual Javal keratometry data and refractive errors.

METHODS

In this retrospective study, 121 eyes of 69 patients with keratoconus (KCN) were fitted with a specific trial set of rigid gas permeable contact lenses based on the standard criterion of "three-point touch" over a 7-year period. Power of the cornea was measured using Javal keratometer. Refractive errors and over refraction of patients were diagnosed using Topcon autorefractometer (RM-A2000) and confirmed by Heine beta 2000 retinoscope.

RESULTS

The results of multiple linear regression showed the following equation: power of contact lens = -14.368 (constant of the final multiple regression model), +0.475 (spherical refraction), and +0.275 (flatter corneal power).

CONCLUSIONS

The results of this study revealed that lens power has a significant relationship with the power of the flat corneal meridian and spherical refractive error in KCN patients. The obtained regression model can be used to shorten patients' chair time and optometric examination for predicting the power of contact lens.

Для цитирования: Birjandi Fereshteh, Ostadimoghaddam Hadi, Yekta Abbasali, Mahjoob Monireh. Initial Power of Rigid Gas Permeable Contact Lenses in Patients with Keratoconus.. Journal of current ophthalmology. 2022. DOI: 10.4103/joco.joco_23_21.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.