MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3174/ajnr.a2115

Медицинская библиотека · AJNR. American journal of neuroradiology · 2010

Emergent self-expanding stent placement for acute intracranial or extracranial internal carotid artery dissection with significant hemodynamic insufficiency.

Jeon P, Kim B M, Kim D I, Shin Y S, Kim K H, Park S I, Kim D J, Suh S H

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: ICAD with hemodynamic insufficiency may present with either fulminant infarct or with progressive neurologic deterioration. The purpose of this study was to evaluate the safety and efficacy of emergent self-expanding stent placement for acute intracranial or extracranial ICAD with significant hemodynamic insufficiency.

MATERIALS AND

METHODS

Eight patients (7 men and 1 woman; age range, 20-55 years; NIHSS score, 5-21) underwent emergent self-expanding stent placement for treatment of significant hemodynamic insufficiency due to acute ICAD. The safety and efficacy of emergent self-expanding stent placement were retrospectively evaluated.

RESULTS

All patients presented with progressive (n = 6) or fluctuating (n = 2) neurologic deficits and revealed markedly decreased perfusion on CT or MR perfusion studies. Conventional angiography revealed acute occlusion (n = 2) or critical stenosis (n = 6) in intracranial (n = 3) or extracranial (n = 5) carotid arteries with a lack of sufficient collaterals. Stent placement was successful in all patients without any procedure-related complications. In all patients, hemodynamic insufficiency was corrected immediately after stent placement, and neurologic symptoms were completely resolved during several days. Mean improvement of the NIHSS score between baseline and discharge was 11.6 (range, 5-21). All patients remained neurologically intact (mRS, 0) during clinical follow-up for a mean of 21 months (range, 8-50 months). Angiographic follow-up was available for 6 patients at 3-12 months. None of the 6 patients revealed residual or in-stent restenosis.

CONCLUSIONS

Self-expanding stent placement is a safe and effective option for selected patients with significant hemodynamic insufficiency due to acute intracranial or extracranial ICAD.

Для цитирования: Jeon P, Kim B M, Kim D I, Shin Y S, Kim K H, Park S I, Kim D J, Suh S H. Emergent self-expanding stent placement for acute intracranial or extracranial internal carotid artery dissection with significant hemodynamic insufficiency.. AJNR. American journal of neuroradiology. 2010. DOI: 10.3174/ajnr.a2115.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.