Sawyer Matthew P, Yong Eric X Z, Marginson Benjamin, Farrell Stephen G, Derbyshire Maresa M, MacIsaac Richard J, Sachithanandan Nirupa
Аннотация
BACKGROUND: Adrenal vein sampling (AVS) is integral to identifying surgically remediable unilateral primary aldosteronism (PA). However, right adrenal vein (AV) cannulation can be challenging, limiting its success. Intra-procedural cortisol assays can improve the reliability of AVS. The aim of this study was to validate the use of semi-quantitative cortisol estimates obtained utilizing a quick cortisol assay (QCA) during AVS procedures at our institution.
METHODS: Retrospective review of results of AVS procedures before and after the introduction of the QCA. Twenty-three AVS procedures were performed with the provisional success determined by intra-procedural QCA. Successful AV cannulation was defined by an AV to peripheral vein cortisol ratio ≥ 4.0 (the selectivity index) from laboratory measurements. The control cohort consisted of 23 consecutive procedures prior to introduction of the QCA.
RESULTS: QCA correctly predicted all AV cannulation attempts. Successful bilateral AV cannulation increased from 52% to 91% of procedures when performed with the QCA (P = 0.01) and adequate cannulation of the right AV increased from 61% to 91% (P = 0.03). There was no increase in procedural time, number of AV cannulation or sampling attempts.
CONCLUSIONS: Point-of-care, semi-quantitative cortisol estimates can be performed accurately during AVS with QCA, facilitating improvements in AVS success rates without increasing procedural time.
METHODS: Retrospective review of results of AVS procedures before and after the introduction of the QCA. Twenty-three AVS procedures were performed with the provisional success determined by intra-procedural QCA. Successful AV cannulation was defined by an AV to peripheral vein cortisol ratio ≥ 4.0 (the selectivity index) from laboratory measurements. The control cohort consisted of 23 consecutive procedures prior to introduction of the QCA.
RESULTS: QCA correctly predicted all AV cannulation attempts. Successful bilateral AV cannulation increased from 52% to 91% of procedures when performed with the QCA (P = 0.01) and adequate cannulation of the right AV increased from 61% to 91% (P = 0.03). There was no increase in procedural time, number of AV cannulation or sampling attempts.