Journal of advanced nursing · 2016
Systematic review and meta-analysis of the diagnostic accuracy of the water swallow test for screening aspiration in stroke patients.
СтатьяМетаанализСистематический обзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Chen Po-Cheng, Chuang Ching-Hui, Leong Chau-Peng, Guo Su-Er, Hsin Yi-Jung
Аннотация
AIM: The aim of this study was to determine the diagnostic accuracy of the water swallow test for screening aspirations in stroke patients.
BACKGROUND: The water swallow test is a simple bedside screening tool for aspiration among stroke patients in nursing practice, but results from different studies have not been combined before.
DESIGN: A systematic review and meta-analysis was conducted to provide a synthetic and critical appraisal of the included studies.
DATA SOURCES: Electronic literature in MEDLINE, EMBASE, CINAHL and other sources were searched systemically in this study. Databases and registers were searched from inception up to 30 April 2015.
REVIEW METHODS: This systematic review was conducted using the recommendations from Cochrane Collaboration for Systematic Reviews of Diagnostic Test Accuracy. Bivariate random-effects models were used to estimate the diagnostic accuracy across those studies. The tool named Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) was used to evaluate the quality of the studies.
RESULTS: There were 770 stroke patients in the 11 studies for the meta-analysis. The water swallow test had sensitivities between 64-79% and specificities between 61-81%. Meta-regression analysis indicated that increasing water volume resulted in higher sensitivity but lower specificity of the water swallow test.
CONCLUSIONS: This systematic review showed that the water swallow test was a useful screening tool for aspiration among stroke patients. The test accuracy was related to the water volume and a 3-oz water swallow test was recommended for aspiration screening in stroke patients.
BACKGROUND: The water swallow test is a simple bedside screening tool for aspiration among stroke patients in nursing practice, but results from different studies have not been combined before.
DESIGN: A systematic review and meta-analysis was conducted to provide a synthetic and critical appraisal of the included studies.
DATA SOURCES: Electronic literature in MEDLINE, EMBASE, CINAHL and other sources were searched systemically in this study. Databases and registers were searched from inception up to 30 April 2015.
REVIEW METHODS: This systematic review was conducted using the recommendations from Cochrane Collaboration for Systematic Reviews of Diagnostic Test Accuracy. Bivariate random-effects models were used to estimate the diagnostic accuracy across those studies. The tool named Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) was used to evaluate the quality of the studies.
RESULTS: There were 770 stroke patients in the 11 studies for the meta-analysis. The water swallow test had sensitivities between 64-79% and specificities between 61-81%. Meta-regression analysis indicated that increasing water volume resulted in higher sensitivity but lower specificity of the water swallow test.
CONCLUSIONS: This systematic review showed that the water swallow test was a useful screening tool for aspiration among stroke patients. The test accuracy was related to the water volume and a 3-oz water swallow test was recommended for aspiration screening in stroke patients.