INTRODUCTION

This study aimed to evaluate the clinical utility of positron emission tomography/magnetic resonance imaging (PET/MRI), especially in comparison with PET/computed tomography (CT), which has been widely used in clinical practice in multiple myeloma.

METHOD: F-18 fluorodeoxyglucose PET/MRI and PET/ CT studies were done at baseline and when at least a partial response to treatment was achieved. These were done for newly-diagnosed myeloma patients who have not had more than 1 cycle of anti-myeloma treatment, or for relapsed and/or refractory myeloma patients before the start of next line of therapy.

RESULTS

PET/MRI correlated significantly with PET/CT, in terms of number of lesions detected, standardised uptake value (SUVmean and SUVmax, both at baseline and post-treatment. PET/MRI and PET/CT correlated with survival at baseline, but not post-treatment.

CONCLUSION

In this study, PET/MRI was more sensitive in detecting early disease and disease resolution post-treatment, compared with PET/CT. However, PET/MRI was less sensitive in detecting lesions in the ribs, clavicle and skull.

Для цитирования: Soekojo Cinnie, Cheng Lenith Tai Jit, Peh Wee Ming, de Mel Sanjay, Ooi Melissa, Nai Ying-Hwey, Reilhac Anthonin, Khor Lih Kin, Chng Wee Joo. Clinical utility of PET/MRI in multiple myeloma.. Annals of the Academy of Medicine, Singapore. 2023. DOI: 10.47102/annals-acadmedsg.2022414.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.