Journal of vascular and interventional radiology : JVIR · 2000
Mechanical versus chemical thrombolysis: an in vitro differentiation of thrombolytic mechanisms.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Greenberg R K, Ouriel K, Srivastava S, Shortell C, Ivancev K, Waldman D, Illig K, Green R
Аннотация
PURPOSE: To assess differing mechanisms of thrombolysis determining time to reperfusion, completeness of thrombus dissolution, and embolic potential.
MATERIALS AND METHODS: An in vitro perfusion model designed to mimic arterial flow conditions was created. Bifurcated limbs allowed continuous flow through one channel and the placement of radiolabeled (iodine-125) thrombus housed in a 5-cm segment of polytetrafluoroethylene graft in the other. The three experimental groups consisted of a standard continuous urokinase infusion, a pulsed pressurized injection of saline, and a similar injection with urokinase. A continuous infusion of 5% dextrose served as a control group. Time to reflow (as assessed with ultrasonic flow monitoring), completeness of thrombus dissolution (I-125 liberated into solution), and the number and size of embolic particles produced (detected by a series of graduated filter sizes) were analyzed.
RESULTS: Time to reflow was significantly faster for both groups when pressurized injections were used (P < .001). There was no reflow in the control arm at 90 minutes. Completeness of thrombus dissolution was higher when a continuous infusion of urokinase was used in comparison to either of the power injection groups or the control (P < .05). The amount of embolic debris produced was significantly lower with a continuous infusion of urokinase compared with either of the power lysis groups (P < .05), but significantly greater than the control arm (P < .001). The size of the embolic particles in the power pulsed lysis groups was significantly decreased by the addition of urokinase (P < .05).
CONCLUSIONS: Reflow is more rapidly established by the use of mechanical means. However, a less complete dissolution of thrombus in conjunction with a greater amount of embolic debris is achieved with this approach. The size of the embolic particles produced is reduced by the addition of a thrombolytic agent.
MATERIALS AND METHODS: An in vitro perfusion model designed to mimic arterial flow conditions was created. Bifurcated limbs allowed continuous flow through one channel and the placement of radiolabeled (iodine-125) thrombus housed in a 5-cm segment of polytetrafluoroethylene graft in the other. The three experimental groups consisted of a standard continuous urokinase infusion, a pulsed pressurized injection of saline, and a similar injection with urokinase. A continuous infusion of 5% dextrose served as a control group. Time to reflow (as assessed with ultrasonic flow monitoring), completeness of thrombus dissolution (I-125 liberated into solution), and the number and size of embolic particles produced (detected by a series of graduated filter sizes) were analyzed.
RESULTS: Time to reflow was significantly faster for both groups when pressurized injections were used (P < .001). There was no reflow in the control arm at 90 minutes. Completeness of thrombus dissolution was higher when a continuous infusion of urokinase was used in comparison to either of the power injection groups or the control (P < .05). The amount of embolic debris produced was significantly lower with a continuous infusion of urokinase compared with either of the power lysis groups (P < .05), but significantly greater than the control arm (P < .001). The size of the embolic particles in the power pulsed lysis groups was significantly decreased by the addition of urokinase (P < .05).
CONCLUSIONS: Reflow is more rapidly established by the use of mechanical means. However, a less complete dissolution of thrombus in conjunction with a greater amount of embolic debris is achieved with this approach. The size of the embolic particles produced is reduced by the addition of a thrombolytic agent.