[Intake of high dose biotin: A cause of artificial hyperthyroidism].

Bouillet B, Rouland A

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Many hormone immunoassays use the biotin streptavidin interaction to immobilize immune complexes. The intake of high dose biotin can interfere with immunoassays using the biotin streptavidin interaction. The biotin-immunoassay interference generates falsely low or falsely high tests of hormones according to the type of immunoassay used.

CASE REPORT: A 70-year-old patient, with progressive multiple sclerosis, was referred to our hospital for thyrotoxicosis. She was found to have markedly elevated thyroid hormones level (T3-T4) and decreased thyrotropin (TSH) level but she had no symptoms of hyperthyroidism. An ingestion of biotin, that is more and more frequent in patients with progressive multiple sclerosis, was found. Thyroid function tests normalized after discontinuation of biotin treatment.

CONCLUSION

The discrepancy between a clinical exam which is not indicative of thyrotoxicosis and markedly abnormal thyroid function tests should lead to a search for biotin intake, which can interfere with thyroid function tests.

Для цитирования: Bouillet B, Rouland A. [Intake of high dose biotin: A cause of artificial hyperthyroidism].. La Revue de medecine interne. 2019. DOI: 10.1016/j.revmed.2019.11.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.