MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/jasms.3c00166

Медицинская библиотека · Journal of the American Society for Mass Spectrometry · 2023

Improved Screening of Monoclonal Gammopathy Patients by MALDI-TOF Mass Spectrometry.

Pečinka Lukáš, Vlachová Monika, Moráň Lukáš, Gregorová Jana, Porokh Volodymyr, Kovačovicová Petra, Almáši Martina, Pour Luděk, Štork Martin, Havel Josef, Ševčíková Sabina, Vaňhara Petr

СтатьяПеревод пока не подготовлен

Аннотация

Monoclonal gammopathies are a group of blood diseases characterized by presence of abnormal immunoglobulins in peripheral blood and/or urine of patients. Multiple myeloma and plasma cell leukemia are monoclonal gammopathies with unclear etiology, caused by malignant transformation of bone marrow plasma cells. Mass spectrometry with matrix-assisted laser desorption/ionization and time-of-flight detection is commonly used for investigation of the peptidome and small proteome of blood plasma with high accuracy, robustness, and cost-effectivity. In addition, mass spectrometry coupled with advanced statistics can be used for molecular profiling, classification, and diagnosis of liquid biopsies and tissue specimens in various malignancies. Despite the fact there have been fully optimized protocols for mass spectrometry of normal blood plasma available for decades, in monoclonal gammopathy patients, the massive alterations of biophysical and biochemical parameters of peripheral blood plasma often limit the mass spectrometry measurements. In this paper, we present a new two-step extraction protocol and demonstrated the enhanced resolution and intensity (>50×) of mass spectra obtained from extracts of peripheral blood plasma from monoclonal gammopathy patients. When coupled with advanced statistics and machine learning, the mass spectra profiles enabled the direct identification, classification, and discrimination of multiple myeloma and plasma cell leukemia patients with high accuracy and precision. A model based on PLS-DA achieved the best performance with 71.5% accuracy (95% confidence interval, CI = 57.1-83.3%) when the 10× repeated 5-fold CV was performed. In summary, the two-step extraction protocol improved the analysis of monoclonal gammopathy peripheral blood plasma samples by mass spectrometry and provided a tool for addressing the complex molecular etiology of monoclonal gammopathies.

Для цитирования: Pečinka Lukáš, Vlachová Monika, Moráň Lukáš, Gregorová Jana, Porokh Volodymyr, Kovačovicová Petra, Almáši Martina, Pour Luděk, Štork Martin, Havel Josef, Ševčíková Sabina, Vaňhara Petr. Improved Screening of Monoclonal Gammopathy Patients by MALDI-TOF Mass Spectrometry.. Journal of the American Society for Mass Spectrometry. 2023. DOI: 10.1021/jasms.3c00166.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.