Preoperative diagnosis of adhesion severity between the abdominal wall and intestinal tract with novel abdominal ultrasound methodology to enhance surgical safety.

Nishino Hiroto, Nishimura Takashi, Miyashita Seikan, Tada Masaharu, Fujimoto Yasuhiro, Fujimoto Jiro, Iijima Hiroko, Hatano Etsuro

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Adhesions between the abdominal wall and intestinal tract from previous surgeries can complicate reoperations; however, predicting the extent of adhesions preoperatively is difficult. This study aimed to develop a straightforward approach for predicting adhesion severity using a novel abdominal ultrasound technique that quantifies the displacement of motion vectors of two organs to enhance surgical safety. The efficacy of this methodology was assessed experimentally and clinically.

METHODS

Using Aplio500T, a system we developed, we measured the displacement of the upper peritoneum and intestinal tract as a vector difference and computed the motion difference ratio. Twenty-five rats were randomized into surgery and nonsurgery groups. The motion difference ratio was assessed 7 days after laparotomy to classify adhesions. In a clinical trial, 51 patients undergoing hepatobiliary pancreatic surgery were evaluated for the motion difference ratio within 3 days preoperatively. Intraoperatively, adhesion severity was rated and compared with the motion difference ratio. A receiver operating characteristic curve was used to appraise the diagnostic value of the motion difference ratio.

RESULTS

In the animal experiment, the adhesion group exhibited a significantly higher motion difference ratio than the no-adhesion group (0.006 ± 0.141 vs 0.435 ± 0.220, P < .001). In the clinical trial, the no-adhesion or no-laparotomy group had a motion difference ratio of 0.128 ± 0.074; mild-adhesion group, 0.143 ± 0.170; moderate-adhesion group, 0.326 ± 0.153; and high-adhesion group, 0.427 ± 0.152. The motion difference ratio receiver operating characteristic curve to diagnose the adhesion level (≥moderate) was 0.938, indicating its high diagnostic value (cut-off 0.204).

CONCLUSION

This methodology may preoperatively predict moderate-to-high adhesions.

Для цитирования: Nishino Hiroto, Nishimura Takashi, Miyashita Seikan, Tada Masaharu, Fujimoto Yasuhiro, Fujimoto Jiro, Iijima Hiroko, Hatano Etsuro. Preoperative diagnosis of adhesion severity between the abdominal wall and intestinal tract with novel abdominal ultrasound methodology to enhance surgical safety.. Surgery. 2024. DOI: 10.1016/j.surg.2024.04.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.