DOI 10.1080/10669817.2024.2355007
Navigating the layers of concern for safe dry needling of the rectus abdominis: a cadaveric study.
Аннотация
OBJECTIVES
To assess needle placement accuracy in the rectus abdominis (RA) muscle during dry needling (DN) without entering the peritoneum.
METHODS
Two physical therapists performed DN on a cadaver, making 10 attempts each to needle the RA without entering the peritoneum. Techniques followed two common DN approaches. Ultrasound verified needle depth and safety.
RESULTS
Seventy percent of attempts were recorded as safe needle placement, while 30% were unsafe. Accurate RA needle placement without peritoneal entry occurred in 55% of attempts.
DISCUSSION/
CONCLUSION
Inadvertent peritoneal needle placement during RA DN poses risks regardless of experience. Ultrasound guidance may enhance safety and precision in clinical practice.