m+Medelevator.RU
← Поиск публикаций
Bioanalysis · 2013

Rapid detection of carbapenemase activity through monitoring ertapenem hydrolysis in Enterobacteriaceae with LC-MS/MS.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Peaper David R, Kulkarni Mandar V, Tichy Alexandra N, Jarvis Michael, Murray Thomas S, Hodsdon Michael E

Аннотация

BACKGROUND: Bacteria are increasingly resistant to antibiotics used to treat life-threatening infections in critically ill patients. The carbapenems represent the last line of defense against Gram-negative rods that are increasingly resistant to all other classes of β-lactam antibiotics used to treat life-threatening infections in critically ill patients. Carbapenem resistance in Gram-negative rods is most commonly caused by expression of carbapenemases, enzymes that hydrolyze the β-lactam ring of carbapenem antibiotics rendering them inactive. All of the available diagnostic tests rely on bacterial growth rendering them time consuming; therefore, rapid diagnostic tests are needed to identify multidrug (including carbapenem)-resistant bacteria.

RESULTS: We report the development of a novel LC-MS/MS method that detects carbapenemase activity from bacterial isolates. Incubation of a bacterial suspension with physiological levels of ertapenem leads to carbapenemase-mediated drug hydrolysis that produces a specific metabolite with an 18 Da increase in m/z within 1 h. Using the ratio of metabolite:parent, detected by LC-MS/MS from the culture, the sensitivity, specificity and a threshold cutoff for carbapenemase production (interpretive criteria) have been determined.

CONCLUSION: A 100% correlation of our LC-MS/MS assay with the modified Hodge test (functional test for carbapenemase production) and PCR emphasizes the robust nature of this assay. The assay requires minimal hands-on time and a straightforward protocol allowing convenient implementation into clinical laboratories. Inclusion of stable isotope-labeled standard will further increase the robustness of the assay. This assay offers several advantages over other similar assays that use MALDI-TOF MS analysis.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты